Donaldson Torit DB-800 Скачать руководство пользователя страница 4

1

Donaldson Company, Inc.

Improper operation of dust collectors and/or dust control systems may contribute to conditions in a work 

area or facility which could result in severe personal injury, and product or property damage. All dust 

collection equipment should be used only for its intended purpose and should be properly selected and sized 

for its intended use.
Process owners have important responsibilities relating to identifying and addressing potential hazards in 

their processes. When the potential for handling combustible dust exists within a process the process owner 

should include combustion hazards in their risk management activities and should comply with applicable 

codes and standards related to combustible dust.
Electrical installation must be performed by a qualified electrician.
This equipment is not designed to support site ducts, piping, or electrical services. All ducts, piping, or 

electrical services must be adequately supported to prevent injury and/or property damage.
Site selection must account for wind, seismic zone, and other load conditions.
Equipment may reach peak sound pressure levels above 80 dB (A). Noise levels should be considered when 

selecting collector location.

Combustible Dust Hazards 

Among other considerations, the current NFPA standards require owners whose processes involve potentially 

combustible materials to have a current Dust Hazard Analysis, which can serve as the foundation for their process 

hazard mitigation strategy. Mitigation may include but is not limited to:

•  Prevention of all ignition sources from entering any dust collection equipment.
•  Selection and implementation of fire and explosion mitigation, suppression, and isolation strategies 

appropriate for the risks in their process.

•  Development and use of work practices to maintain safe operating conditions, and to ensure combustible dust 

does not accumulate within their plant or process equipment.

Donaldson designs, manufactures, and sells industrial air filtration products for a wide variety of applications. Some 

applications may include processes or materials with inherent fire and explosion hazards. Donaldson is neither an 

expert nor a certified consultant in fire, spark, or explosion detection, suppression, or control. Donaldson does not 

provide engineering consulting services related to process or dust hazard analyses, or code and standard compliance. 

Complying with applicable codes and standards and managing the risks associated with the process or materials 

remains the responsibility of the process owner/operator. Donaldson may provide referrals to consultants, suppliers 

of equipment or services related to the detection and/or mitigation of sparks, fires and/or explosions, but Donaldson 

does not assume responsibility for any such referrals, nor does Donaldson assume any liability for the fitness of a 

mitigation strategy or product for a particular installation or application. The process owner’s final selection of dust 

collectors and risk mitigation strategies should be based on the outcome of a Dust Hazard / Process Hazard Analysis 

performed by the process owner. Although early engagement of a dust collector supplier provides helpful insights on 

the availability and features of various products, process owners should consult with a combustible dust expert and/or 

a process safety expert before making actual product and mitigation strategy selections.

Donaldson recommends that all industrial air filtration system designs be reviewed and approved by an expert 

consultant who is responsible for the integrity of the system design and compliance with applicable codes and 

standards. It is the process owner’s responsibility to understand the risks in their process and mitigate those risks in 

accordance with all applicable laws, regulations and standards, including those published by the NFPA. Donaldson 

also recommends that proper maintenance and housekeeping procedures and work practices be evaluated, 

developed, and followed to maintain any industrial air filtration products in safe operating condition.

Many factors beyond the control of Donaldson can affect the use and performance of Donaldson products in a 

particular application, including the conditions under which the product is used. Since these factors are uniquely 

within the user’s knowledge and control, it is essential the user evaluate the Donaldson products to determine whether 

the product is fit for the particular purpose and suitable for the user’s application. All products, product specifications, 

and data (airflow, capacity, dimensions, or availability) are subject to change without notice, and may vary by region or 

country.

Safety Communication

Содержание Torit DB-800

Страница 1: ...and warnings in this manual DO NOT operate or perform maintenance on this collector until you have read and understood the instruction and warnings contained within this manual Downdraft Bench DB 800...

Страница 2: ...ipment This manual has been supplied to assist with the installation operation and maintenance for the collector purchased Please read the manual before installing operating or performing maintenance...

Страница 3: ...Support Framing 4 Collector Location 5 Site Selection 5 Hoisting Information 5 Standard Equipment 5 Electrical Wiring 5 Industrial Light Three Phase Units 6 Hinged Side Panels 6 Preliminary Start Up C...

Страница 4: ...r control Donaldson does not provide engineering consulting services related to process or dust hazard analyses or code and standard compliance Complying with applicable codes and standards and managi...

Страница 5: ...r allows on demand filter cleaning Replace filters easily with the one piece EZ Filter Pack and dispose of dust contained in the dust drawer from the front of the unit The Downdraft Bench provides exc...

Страница 6: ...Filter Pack into the clean air chamber and discharges through the clean air outlet The DB 800 is an intermittent duty collector which means that filter cleaning cannot start until the fan is turned OF...

Страница 7: ...te installation and service of this equipment All shipping materials including shipping covers must be removed from the collector prior to or during collector installation Failure to remove shipping m...

Страница 8: ...safety precautions needed for moving and handling the equipment A crane or forklift and qualified operator are recommended for unloading assembly and installation of the collector Location must be cle...

Страница 9: ...rce and switch any two leads on the output side of the fan motor starter 1FU 2FU 3FU 1M 1OL 1T2 1T3 fan motor Disconnect L1 L2 L3 1T1 1L1 1L2 1L3 208 230 460 575 60 3 Motor Starter Wiring Diagram Indu...

Страница 10: ...or near the inlet and outlet of the collector 4 Check that all remote controls are properly wired and all service switches are in the OFF position 5 Check that all optional accessories are installed...

Страница 11: ...2 Monitor pressure drop across filters Abnormal changes in pressure drop may indicate a change in operating conditions and possibly a fault to be corrected 3 Monitor exhaust 4 Monitor dust disposal Op...

Страница 12: ...this is easier when the filter pack is supported with one hand on the bottom side EZ Filter Pack Installation Step 2 Step 1 Steps 1 3 Step 4 loosen wing screws slide to rear 4 Insert banded EZ Filter...

Страница 13: ...y under each side of the EZ Filter Pack Push EZ Filter Pack to bottom of cabinet filter frame 8 Important place one hand under center of EZ Filter Pack Holding EZ Filter Pack against bottom of cabinet...

Страница 14: ...utomatic filter shaker to clean the filters 3 When the cleaning cycle is complete open the filter access door 4 Reach inside the opening grasp the dust drawer edge and pull the dust drawer out of the...

Страница 15: ...pplied Install two 1 8 in NPT male adapters supplied with the gauge into the high and low pressure ports on the side of the gauge 6 Attach the mounting bracket using three 6 32 x 1 4 in screws supplie...

Страница 16: ...nting screws mounting bracket static pressure tee 1 8 in NPT x 90 elbow 1 8 in NPT adapter 1 8 in NPT adapter 3 8 in flat washer dirty air plenum pressure tap location 1 8 in NPT adapter 1 8 in NPT x...

Страница 17: ...turer s rated amps Electrical circuit overload Check that the power supply circuit has sufficient power to run all equipment Inlet too large for collector rating Contact installer of dust collection e...

Страница 18: ...____ Collected Dust __________________________________________________________________________________ Dust Properties Kst________________Pmax_______________ MIE_____________ MEC___________________ Ac...

Страница 19: ...regoing warranty on services Products manufactured by a third party Third Party Product may constitute contain be contained in incorporated into attached to or packaged together with the goods Buyer a...

Страница 20: ...america Email IndustrialAir donaldson com Phone 52 449 300 2442 South Africa Email SAMarketing donaldson com Phone 27 11 997 6000 Southeast Asia IAF Email IAF SEA donaldson com Phone 65 63117373 Impor...