background image

IOM 7568201 (ENG), Revision 3 (June 2019) ©2003 Donaldson Company, Inc.  

Donaldson, Torit, EZ Filter Pack, and the color blue are marks of Donaldson Company, Inc. All other marks belong to their respective owners.

Donaldson Company, Inc. 

Minneapolis, MN

donaldsontorit.com • shop.donaldson.com

North America

Email: [email protected]  

Phone: (USA): 800-365-1331 • (MX): 800-343-3639

Australasia

Email: [email protected] 

Phone: +61 2 4350 2000 

Toll Free: (AU) 1800 345 837 • (NZ) 0800 743 387

China IAF

Email: [email protected] 

Phone: (86) 400-820-1038

Donaldson Europe B.V.B.A.

Email: [email protected] 

Phone: + 32 (0) 16 38 38 11

India

Email: [email protected] 

Phone: +91 124 4807400 

Toll Free: 18001035018

Latinoamerica

Email: [email protected] 

Phone: +52 449 300 2442

South Africa

Email: [email protected] 

Phone: +27 11 997 6000

Southeast Asia IAF

Email: [email protected] 

Phone: (65) 63117373

Important Notice

Many factors beyond the control of Donaldson can affect the use and performance of Donaldson products in a particular application, including the conditions under which the product is used. Since these 

factors are uniquely within the user’s knowledge and control, it is essential the user evaluate the products to determine whether the product is fit for the particular purpose and suitable for the user’s application. 

All products, product specifications, availability and data are subject to change without notice, and may vary by region or country.

Significantly improve the performance of your collector with genuine Donaldson Torit 
replacement filters and parts. 

Call Donaldson Torit at 800-365-1331.

Содержание Torit DB-800

Страница 1: ...and warnings in this manual DO NOT operate or perform maintenance on this collector until you have read and understood the instruction and warnings contained within this manual Downdraft Bench DB 800...

Страница 2: ...ipment This manual has been supplied to assist with the installation operation and maintenance for the collector purchased Please read the manual before installing operating or performing maintenance...

Страница 3: ...Support Framing 4 Collector Location 5 Site Selection 5 Hoisting Information 5 Standard Equipment 5 Electrical Wiring 5 Industrial Light Three Phase Units 6 Hinged Side Panels 6 Preliminary Start Up C...

Страница 4: ...r control Donaldson does not provide engineering consulting services related to process or dust hazard analyses or code and standard compliance Complying with applicable codes and standards and managi...

Страница 5: ...r allows on demand filter cleaning Replace filters easily with the one piece EZ Filter Pack and dispose of dust contained in the dust drawer from the front of the unit The Downdraft Bench provides exc...

Страница 6: ...Filter Pack into the clean air chamber and discharges through the clean air outlet The DB 800 is an intermittent duty collector which means that filter cleaning cannot start until the fan is turned OF...

Страница 7: ...te installation and service of this equipment All shipping materials including shipping covers must be removed from the collector prior to or during collector installation Failure to remove shipping m...

Страница 8: ...safety precautions needed for moving and handling the equipment A crane or forklift and qualified operator are recommended for unloading assembly and installation of the collector Location must be cle...

Страница 9: ...rce and switch any two leads on the output side of the fan motor starter 1FU 2FU 3FU 1M 1OL 1T2 1T3 fan motor Disconnect L1 L2 L3 1T1 1L1 1L2 1L3 208 230 460 575 60 3 Motor Starter Wiring Diagram Indu...

Страница 10: ...or near the inlet and outlet of the collector 4 Check that all remote controls are properly wired and all service switches are in the OFF position 5 Check that all optional accessories are installed...

Страница 11: ...2 Monitor pressure drop across filters Abnormal changes in pressure drop may indicate a change in operating conditions and possibly a fault to be corrected 3 Monitor exhaust 4 Monitor dust disposal Op...

Страница 12: ...this is easier when the filter pack is supported with one hand on the bottom side EZ Filter Pack Installation Step 2 Step 1 Steps 1 3 Step 4 loosen wing screws slide to rear 4 Insert banded EZ Filter...

Страница 13: ...y under each side of the EZ Filter Pack Push EZ Filter Pack to bottom of cabinet filter frame 8 Important place one hand under center of EZ Filter Pack Holding EZ Filter Pack against bottom of cabinet...

Страница 14: ...utomatic filter shaker to clean the filters 3 When the cleaning cycle is complete open the filter access door 4 Reach inside the opening grasp the dust drawer edge and pull the dust drawer out of the...

Страница 15: ...pplied Install two 1 8 in NPT male adapters supplied with the gauge into the high and low pressure ports on the side of the gauge 6 Attach the mounting bracket using three 6 32 x 1 4 in screws supplie...

Страница 16: ...nting screws mounting bracket static pressure tee 1 8 in NPT x 90 elbow 1 8 in NPT adapter 1 8 in NPT adapter 3 8 in flat washer dirty air plenum pressure tap location 1 8 in NPT adapter 1 8 in NPT x...

Страница 17: ...turer s rated amps Electrical circuit overload Check that the power supply circuit has sufficient power to run all equipment Inlet too large for collector rating Contact installer of dust collection e...

Страница 18: ...____ Collected Dust __________________________________________________________________________________ Dust Properties Kst________________Pmax_______________ MIE_____________ MEC___________________ Ac...

Страница 19: ...regoing warranty on services Products manufactured by a third party Third Party Product may constitute contain be contained in incorporated into attached to or packaged together with the goods Buyer a...

Страница 20: ...america Email IndustrialAir donaldson com Phone 52 449 300 2442 South Africa Email SAMarketing donaldson com Phone 27 11 997 6000 Southeast Asia IAF Email IAF SEA donaldson com Phone 65 63117373 Impor...