WSO Mist Collector, WSO 20, 25-1, 25-2, and 25-3
12
P-Trap Installation
Ensure collected material
properly flows through the
P-Trap. The P-Trap dimensions should
accommodate a column of coolant greater
than the static capacity of the fan to avoid
coolant pooling in the collector and potentially
causing property damage.
1. Install the P-Trap as shown in P-Trap Installation.
2. Position the P-Trap outlet to the proper location and
tighten the union.
3. Plumb the P-Trap to a receptacle or install a return
line back to the machine center.
4. Fill P-Trap before starting unit.
Note: The characteristics of some machining fluids
change with time, use, and exposure to air.
Check the condition of the collected fluid
before re-using.
Inlet Collar Installation
(WSO 20 and 25-1)
1. Install the inlet collar to the desired inlet location
using the supplied sealant and hardware.
2. For single-inlet configurations, install the inlet
blank to the inlet opposite the inlet collar using the
supplied sealant and hardware.
(WSO 25-2 and 25-3)
1. Refer to the Specification Control Drawing to get the
dimensions and bolt pattern of the inlet. Typically,
a rectangle-to-round transition, custom to your
particular installation, is obtained from the ducting
supplier. Install the rectangle-to-round transition to
the desired inlet location using the supplied sealant
and hardware.
2. For single-inlet configurations, install the inlet
blank to the inlet opposite the inlet collar using the
supplied sealant and hardware.
hopper
maximum
fill level
union
pipe plug
NPT pipe
P-Trap Installation
sealant
inlet collar
Inlet Collar Installation, WSO 25-1 shown
NOTICE
Содержание WSO 20
Страница 1: ...IOM AK0300801 ENG Revision 3...
Страница 5: ...200 Volt 380 Volt 3 Ph 50Hz 60 Hz...
Страница 27: ......
Страница 31: ......