11
Donaldson Company, Inc.
Ceiling Mount (WSO 20 and 25-1)
Failure to lift the collector
correctly can result in severe
personal injury or property damage.
Use appropriate lifting equipment and adopt
all safety precautions needed for moving and
handling the equipment.
A crane or forklift is recommended for
unloading, assembly, and installation of the
collector.
Location must be clear of all obstructions,
such as utility lines or roof overhang.
Ensure weight of oil-laden unit plus weight
of required materials and equipment will be
adequately supported. Failure to comply may
result in personal injury and/or property damage.
Top View
45°
Front View
60°
Isometric View
customer-supplied
chain or cable
eye bolt
Ceiling Mount Installation, WSO 20 shown
1. Verify that the ceiling attachment points can bear the
live load.
2. Use properly sized cable or chain to attach to each
of the four WSO attachment lugs (WSO 25-1) or
eyebolts (WSO 20) to suspend the unit from the
ceiling.
3. To prevent sway, position the chain or cable to form
a 60 degree angle to the top of the unit and a 45
degree angle along the sides.