Donaldson Company, Inc.
20
hopper
fluid
head
union
pipe plug
NPT pipe
P-Trap Installation
CAUTION!
Ensure collected material properly flows
through the P-trap. Improperly operating
P-trap may result in propery damage.
P-Trap Installation
Note:
Ensure P-trap is designed with sufficient
fluid head to overcome blower static
capabilities. An incorrectly sized P-trap
will result in coolant pooling within the
inlet plenum.
1. Install the P-trap as shown in P-Trap
Installation.
2. Position the P-trap outlet to the proper location
and tighten the union.
3. Plumb the P-trap to a receptacle or install a
return line back to the machine center.
4. Fill P-trap before starting unit.
Note:
The characteristics of some machining
fluids change with time, use, and
exposure to air. Check the condition of
the collected fluid before re-using.