![Donaldson Torit UMA 100H Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/donaldson-torit/uma-100h/uma-100h_installation-operation-and-maintenance-manual_2520677011.webp)
Installation, Operation and Maintenance Manual
Unimaster Dust Collectors – Series UMA 40-750
11
INSTALLATION
All collectors are delivered to site either upright or laid on their side, in one piece
or in a number of pieces depending on their configuration.
Lifting brackets are provided on all collectors except the UMA 40 and 40MM.
They are also fitted to the UMA 100 to 750 bottom assemblies when supplied
separate to the main filter case. Where headroom is restricted, a fork lifting option
is available on all collectors except for the UMA 750V. The UMA 750 fan type
collectors have a lifting beam within the fan chamber, while the smaller collectors
are lifted from underneath the seal frame after filter assembly removal.
General guidance to lifting
During all lifting operations a crane or fork lift with an adequate SWL (safe
working load) must be used. (Refer to lifting labels located adjacent to
lifting fixture for weight of equipment supplied by Donaldson).
It may be necessary to guide the collector during lifting to prevent
excessive swing.
If a fork lift is used to lift the collector using the lifting brackets, a suitable
lifting attachment must be used to prevent the chains slipping off the
forks (see fig. 2).
If chains or slings are used they must have an adequate SWL (safe
working load). (Refer to lifting labels located adjacent to lifting brackets
for weight of equipment supplied by Donaldson).
Figure 4 Lifting collector to vertical position
≤
90
°
≤
90
°
OR
PREFERRED
LIFTING METHOD