25
Donaldson Company, Inc.
Problem
Probable Cause
Remedy
Insufficient airflow
continued
Pulse cleaning not energized
Use a voltmeter to check the solenoid valves in the
control panel. Check pneumatic lines for kinks or
obstructions.
Pulse valves leaking
compressed air
Lock out all electrical power to the unit and bleed
the compressed air supply. Check for debris, valve
wear, pneumatic tubing fault, or diaphragm failure by
removing the diaphragm cover on the pulse valves.
Check for solenoid leaks or damage. If pulse valves
or solenoid valves and tubing are damaged, replace.
No display on the Delta P
Controller
No power to the controller
Use a voltmeter to check for supply voltage.
Fuse blown
Check the fuse in the control panel. See wiring
diagram inside the control panel. Replace if
necessary.
Display on Delta P
Controller does not read
zero when at rest
Out of calibration
Recalibrate as described in Delta P Maintenance
Manual
Delta P Controller ON, but
cleaning system does not
start
Pressure tubing disconnected,
ruptured, or plugged
Check tubing for kinks, breaks, contamination, or
loose connections.
High Pressure On or Low
Pressure Off setpoint not
adjusted for system conditions
Adjust setpoints to current conditions.
Pulse cleaning never stops Pressure switch not operating
correctly
Check pressure switch inside the control panel.
High Pressure On or Low
Pressure Off setpoint not
adjusted for system conditions
Adjust setpoints to current conditions.
Pressure tubing disconnected,
ruptured, plugged, or kinked
Check tubing for kinks, breaks, contamination, or
loose connections.
Alarm light is ON
Alarm setpoint too low
Adjust to a higher value.
Excess pressure drop
Check cleaning system and compressed air supply.
Replace filter packs if filter packs do not clean down.
Pressure tubing disconnected,
ruptured, plugged, or kinked
Check tubing for kinks, breaks, contamination, or
loose connections.
Delta P Controller arrow
keys to not work
Improper operation
Press and hold one of the three setpoint keys to use
arrow keys.
Troubleshooting
Содержание PowerCore CPV-1
Страница 29: ...Torit PowerCore CPV 1 to CPV 12 26 Service Notes Date Service Performed Notes...
Страница 30: ...27 Donaldson Company Inc Service Notes Date Service Performed Notes...
Страница 31: ......