Downflo Oval, DFO 1-1 to 3-3
8
Provisional Anchor Bolt Recommendations
1. Consider Hilti HIT-HY 200 Anchor System or
equivalent. Quantity of anchor bolts should match the
number of holes provided in the base plates.
2. Anchor diameter is typically 1/8-in less than
baseplate hole diameter.
3. Corrosive environment or outdoor installation may
require stainless steel anchors.
Typical Foundation Anchor
Anchor should project a
minimum of 1 3/4-in and
account for nut, washer,
base plate and shims/
grout.
Embedment depth
(suitable for the
physical properties of
the foundation).
Collector Anchoring
Anchors must comply with local
code requirements and must be
capable of supporting dead, live, wind, seismic,
and other applicable loads.
Anchor sizes shown are provisional, as final
anchor sizing will depend on jobsite load
conditions, collector location, foundation/
framing design variables and local codes.
Consult a qualified engineer for final selection
of suitable anchors.
Tighten all hardware before removing crane
to prevent personal injury and/or property
damage.
Prepare the foundation or support framing in the
selected location. Locate and install anchors.