Icono 

Descripción / Función 

WIFI configuration (WPS)

Fast double press SET to enter Wi-Fi 

configuration, use router WPS function. 

 

Press SET for display the hour. Rotate the knob to set wireless 
communication channel (0-19) (default channel is channel 10). Press SET 
to validate. 

 

Rotate the knob and press SET to set hysteresis ON value (Range 0-2 ºC 
in 0,1 increment). e.g. If target temperature set at 25 ºC and hysteresis ON 
temp at 0,5 ºC, when room temperature at 24,5 ºC transmitter sends 
heating request signal to boiler. Press SET to validate. 

 

Rotate the knob and press SET to set hysteresis OFF value (Range 0-2 ºC 
in 0,1 increment). e.g. If target temperature set at 25 ºC and hysteresis ON 
temp at 0,5 ºC, when room temperature at 25,5 ºC transmitter sends 
heating off signal to boiler. Press SET to validate. 

No functional parameter. 

Rotate the knob and press SET to exit current settings. 

Содержание MyDOMO

Страница 1: ...User manual ...

Страница 2: ...alación de la App y Configuración del Wi Fi 4 5 MyDomo Wi fi Remote Control Transmitter 13 6 Receiver 19 7 Technical Specifications 22 Thank you for choosing MyDomo Please read this manual before installing It is recommended that this device is installed by a qualified electrician ...

Страница 3: ...fi Remote Control Transmitter 1 Receiver 1 Manual x1 Accessory package Dowels 2 Fix screws 2 White sticky pads 2 Black sticky magnetic pads 3 USB cable 1 AC DC Adapter 1 MyDomo Receiver Manual USB cable Adapter Accessory package ...

Страница 4: ...d off the system when demanded Changing DHW set temperature Adjusting the operation power of the boiler automatically as it approaches to the desired set temperature Getting to know the alarms 3 RF PAIRING RADIO FRECUENCY Long press light on receiver green light is on and red light flicks regularly Then long press MODE button MyDomo to enter coupling state Displaying on transmitter is changed to w...

Страница 5: ...ch MyDomo For iOS operating system go to App Store and search MyDomo Step 2 Create an account Please make sure your device is connected to Wi Fi successfully 1 Open App MyDomo and tap Register 2 Create an account 3 Log in You will need to enter device ID to proceed ID code is to be found at the back of MyDomo or on package box ...

Страница 6: ...tablished you will be able to use mobile networks to control MyDomo application on your device 1 Tap in top right corner of the Sign In interface and follow the instructions on APP to connect MyDomo to Wi Fi You will need to enter device ID to proceed ID code is to be found at the back of thermostat or on package box Alternatively you can carry out step 2 before step 1 ...

Страница 7: ...Go to top left menu and go to Account Input location information where MyDomo is being installed at Weather Location line 2 Tap in the Outdoor weather temperature and choose the location Outdoor weather information Target room temperature Current room temperature Heating status 1 2 3 4 ...

Страница 8: ...rner the below screen appears Set the desired temperature and time Tap the program screen again to set temperatures and heating time for another period of time in the same day if needed If an adjusted program to be copied to another day or set of days go to top right corner APPLY TO and select the days desired the same operation to be repeated to ...

Страница 9: ...ogram needed switch to MANUAL MODE and set per needs To go back to the original PROGRAM MODE just switch it back OFF MODE When set to OFF MODE MyDomo only heats when the room temperature drops below 5 ºC to prevent frost damage ...

Страница 10: ... a DOMUSA TEKNIK boiler with MyDomo it is necessary to examine their compatibility with the boiler Boilers with Remote Control option are compatibles with MyDomo Enter Control my boiler to see your boiler working state ...

Страница 11: ...splaying their current and target temperatures Outdoor weather information DHW target temperature Boiler temperature Heating state DHW current temperature Boiler flame state Water pressure Boiler status error codes Boiler target temperature 1 7 2 3 4 5 6 9 8 ...

Страница 12: ...11 SUMMER MODE In this mode heating service is deactivated OFF MODE When set to OFF MODE MyDomo only heats when the room temperature drops below 5 ºC to prevent frost damage ...

Страница 13: ...12 Go to top right corner tap drop down menu tap Boiler Information to see boiler working data and error codes ...

Страница 14: ... LED light up for 3 seconds upon powering on followed by version of built in hardware MODE Press to select MANUAL MODE PROGRAM MODE or OFF MODE SET Press SET to change between room temperature and hour Press 5 seconds to connect Wi Fi Knob Rotate to adjust temperature valid only in MANUAL MODE Room temperature sensor RESET Reboot screen appears after reset button pressed Micro USB port to supply p...

Страница 15: ...ºC in 0 1 increment e g If target temperature set at 25 ºC and hysteresis ON temp at 0 5 ºC when room temperature at 24 5 ºC transmitter sends heating request signal to boiler Press SET to validate Rotate the knob and press SET to set hysteresis OFF value Range 0 2 ºC in 0 1 increment e g If target temperature set at 25 ºC and hysteresis ON temp at 0 5 ºC when room temperature at 25 5 ºC transmitt...

Страница 16: ...rmometer near the thermostat that you keep a minimum of 50 minutes Press and hold SET and MODE until the temperature remains on the display only Enter the thermometer indicated value standard by turning the wheel on the side of thermostat and press the SET Warning the thermostat does not show correct temperature value and does not allow calibration in less than 50 minutes after the electrical supp...

Страница 17: ...he display of the thermostat will be reduced during the night This function is automatically activated during night hours 20 00 8 00 Current room temperature PROGRAM MODE Wi Fi connection OFF MODE MANUAL MODE Heating state 1 2 3 4 5 6 ...

Страница 18: ...port Also please note that the server may be down for a short while for maintenance Try to be always updated with the last version of the MyDomo App RADIO FRECUENCY RF CONNECTION STATE Slow flicking RF communication error Fast flicking RF hardware error On RF communication is normal Radio communication inside the house building structure can be influenced by many factors concrete structure metal o...

Страница 19: ...re from the side of MyDomo or from App PROGRAM MODE Check the schedule from the App on your smart devices OFF MODE MyDomo only heats when the room temperature drops below 5 ºC to prevent frost damage HEATING STATE Flicking Communication error On Heating is on Off Heating is off ...

Страница 20: ...orized personnel Before connection check that the command of the terminals is NOT 220V Receiver Boiler connection 1 There are 4 wires from receivers wires from receiver labelled OT are to be connected with boilers with electronic control Wires labelled ON OFF are to be connected with analogical boilers 2 Use black magnetic pad or the screws to fix the receiver to a proper place OT ON OFF ...

Страница 21: ...20 Schematic Diagram Boiler Receiver Servidor AC DC Adaptor USB cable MyDomo Router Wi Fi RF ...

Страница 22: ...F Communication Relay OT Communication Flame Boiler fault Off On Off Regular flicking Off Irregular flicking On Off On Regular flicking On Irregular flicking Regular flicking On Regular flicking Irregular flicking Regular flicking Off Irregular flicking Regular flicking Irregular flicking Off Irregular flicking On ...

Страница 23: ...6 x 86 x 35mm Receiver dimensions 86 x 86 x 20mm Housing material ABS PC Aluminium Temperature sensor Built in Boiler control protocol Open Therm v2 1 Wi Fi Wi Fi standard 802 11b g n Frequency 2 412GHz 2 484GHz Wireless frequency band 868MHZ FSK RF transmit range 100m in the open air Safety mode WEP WPA PSK WPA2 PSK Net protocol IPv4 TCP Net type STA ...

Страница 24: ... San Esteban auzoa z g 20730 AZPEITIA 20737 ERREZIL Gipuzkoa Telf 34 943 813 899 www domusateknik com DOMUSA TEKNIK reserves the right to make modifications of any kind to tis product characteristics without prior notice CDOC001670 CDOC001670 09 17 ...

Отзывы: