Fusion Hybrid Oil
36
16.5
Combustion line adjustment
To adjust the combustion line, loosen the combustion line blocking screw
“BL”
. Turn the line
regulator
“RL”
clockwise to increase the airflow and anticlockwise to decrease it. After adjustment,
tighten the combustion line blocking screw
“BR”
.
BL
RL
+
-
3 mm
0
1
16.6
Correct position of electrodes
To ensure correct ignition of the
“Domestic”
burner, the measurements shown in the diagram must
be observed. In addition, ensure that the electrode fixing screws have been screwed in place before
replacing the flame tube.
2/3 mm
3 mm
16.7
Oil pressure adjustment
To adjust the oil pump pressure, turn the screw
(1)
clockwise to increase the pressure, and
anticlockwise to decrease it.
1 - Pressure adjustment.
2 - Vacuum gauge point.
3 - Valve.
4 - Manometer point.
5 - Nozzle outlet.
6 - Return.
7 - Intake.
DANFOSS – MOD. BFP 21 L3
3
5
4
2
7
6
1
SUNTEC - MOD. AS47C