Fusion Hybrid Oil
22
For a better comfort in the air conditioning, by means of the heating selector
(22)
, it is possible to
change the operating mode in air conditioning demand.
By turning the heating selector
(22)
to position the heat pump begins working exclusively in air
conditioning mode. The heat pump stops managing the heating demand by focusing its operation
exclusively on-air conditioning. The DHW demand will be managed according to the DHW selector
(23)
.
By combining the operating modes in the heating selector
(28)
in position
and the DHW
selector
(27)
in position , an uninterrupted air conditioning operation is achieved with the heat
pump, while the support module manages the DHW demand.
6.5
Operation with room thermostat
The
Fusion Hybrid Oil
module features a connection prepared for the installation of a room
thermostat or programmable thermostat (
see
“Connecting the room thermostat”
in this
manual).
This will allow the management of the pack operation depending on the temperature inside
the home. Optionally,
DOMUSA TEKNIK
offers a wide range of such devices in its product catalogue.
The installation of a room thermostat will optimise the installation’s performance, adapting the
heating and air conditioning to the requirements of your home and obtaining enhanced comfort.
Additionally, if the thermostat allows the operating hours to be programmed (chronothermostat), it
can adapt the system to the hours of use of the installation.
7
HEATING CIRCUIT ADJUSTMENT
7.1
Adjustment of the maximum boiler setpoint temperature
The maximum heating setpoint temperature (default 70°C) can be adjusted through the boiler
control thermostat
(20)
, in order to adjust it to the characteristics of each installation, optimising
the energy efficiency of the system.
8
DRAINAGE
The draining of the water from the primary installation is carried out by opening the drain valve
(19)
,
located inside the module, in the bottom right. Connect a flexible tube to this valve and run it to a
drain. It is advisable to open the drain valves present in the Heating/Air conditioning installation so
that air enters the circuit. Once the emptying operation has been carried out, close the valve and
disconnect the flexible tube.
During the emptying process, it is advisable to turn off both the module and the heat
pump and disconnect them from the power supply.