INSTALLATION MANUAL
EN
WARRANTY:
The warranty on the device is valid only if powered by
a power supply provided by DOMUS Line. The
warranty’s general terms and conditions for this
device are available at
www.domusline.com
CAUTION
ONLY SUITABLE FOR DRY LOCATION
CABINET USE ONLY
USE ONLY 12Vdc CLASS 2 POWER SUPPPLY
TYPE IC RECESSED – INHERENTLY PROTECTED
TO REDUCE THE RISK OF FIRE DO NOT INSTALL
CLOSER THAN 10mm TO THE CABINET WALL OR IN A
COMPARTMENT SMALLER THAN 300mm BY 300mm
LAB
is a switchless component; therefore, it must be
switched on using a separate switch.
- If it is necessary to connect more than one device to
the power supply, ensure that the total sum of the
power absorbed by the luminaires (refer to the data
indicated on the nameplate of the product label),
does not exceed the maximum permitted by the
converter.
- DOMUS Line guarantees the product only if supplied
with its own power supply converter.
HOW THE LAB IR OPERATES (IR sensor) Diagram 6
The luminaire is simply switched on with opening of
the door that is positioned in front of the sensor (C).
The luminaire is switched off 10 seconds after the
door is closed. The luminaire has a safety program
that switches the
LAB IR
off after 2 hours of
continuous operation with the door open.
WARNING:
- This luminaire must be connected
directly to the electricity power supply and must
never be connected downstream of other electronic
switches, or be positioned near electromagnetic
sources, or be exposed to light beams.
WARNING:
The Led MODULE, the power supply cable or any
switch used, are not replaceable, therefore in case of
damage the device must be entirely substituted.