(8)
EPT052026 Issue 1 February 2019
PRINTER SETTINGS
Notes: (1)
A USB keyboard is required to setup the printer.
(2)
Ensure the printer’s RS485 settings and the PLC or PC’s com port settings are set to
the same values.
To configure the printer for RS485 communication:
(1) From the main menu, highlight
Settings.
(2) Press the
Enter
button.
(3) Move the cursor to highlight
RS485.
(4) Press the
Enter
button.
(5) The following settings can now be configured:
(6) Press
ESC
to return to the main menu.
End of procedure.
Status:
Enable or Disable RS485 communication.
Address
Set a unique address for each printer. The value is set in decimal form
from 1 to 255.
See “DECIMAL/HEXADECIMAL CONVERSION TABLE” on page 35.
Baud rate:
Set the speed of communication from 9600 to 115200.
Parity:
Set the protocol check sum:
• Odd
• Even
• None
Data bits
Select 8 if Parity is set to None.
Select 9 if Parity is set to Odd or Even.
Stop bits
Select 1 or 2