EPT052026 Issue 1 February 2019
(15)
Set message
^1M01CS`@0`
*x
`@1`
*y
`@2`
*z
`@3`
*p
`@4`
*r
`@5`
*q
\0
*x
: Message string for line
1. Range = 0-100
characters.
*y
: Message string for line
2. Range = 0-100
characters.
*z
: Message string for line
3. Range = 0-100
characters.
*p
: Message string for line
4. Range = 0-100
characters.
*r
: Message string for line
5. Range = 0-100
characters.
*q
: Message string for line
6. Range = 0-100
characters.
To insert a variable item
into the message:
Counter = C
x
with
x
: 0-5
Shift code = S
x
with
x:
0-
2
BoxLot = S
xy
with
x:
0,
y
:
0-3
Time = T
Date = D
x
with
x
: 0-4
Expire date = E
x
with x:
0-4
Barcode = R
Logo = L
x
with
x
: 0-3
Note:
Stop printing
before sending the
message.
^1M01CS`@0`ABC`@1`XYZ`@2`I
HG`@3`WER`@4`TUV`@5`OPQ\0
= Print “ABC” on line 1, “XYZ”
on line 2, “IHG” on line 3,
“WER” on line 4, “TUV” on line 5
and “OPQ” on line 6.
To insert a counter to line 1 of
message that has been setup
with counter setup command,
use this command:
^1M01CS`@0`CounterSample:
`C0`. Time: `T`. Date: `D0`. Expire
date:
`E0``@1`XYZ`@2`IHG`@3`WER`@
4`TUV`@5`OPQ
8080
Table 1: PC to Printer
Operation
Command
Parameter
Examples
UDP Port
Содержание G20I
Страница 1: ...Domino G20i RS485 Guide G20i...
Страница 2: ...2 EPT052026 Issue 1 February 2019 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 4: ...4 EPT052026 Issue 1 February 2019 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 6: ...6 EPT052026 Issue 1 February 2019 AMENDMENT RECORD Amendment Date All parts at Issue 1 February 2019...