EPT052026 Issue 1 February 2019
(17)
Set counter
^1C01CS
*x*y*z*
a*b*c*d*e
\0
*x
: Counter number.
Range = 0-5. This is the
name of the counter that
will be stored on the
printer.
*y
=0: Count upwards.
*y
=1: Count downwards.
*z
=0: Do not fill zeros.
*z
=1: Fill zeros.
*a
: Counter steps. Range
= 000-250 (mandatory 3
characters).
*b
: Counter start value.
Range = 0000000001-
2000000000 (mandatory
10 characters).
*c
: Current counter value.
Range = 0000000001-
2000000000 (mandatory
10 characters).
*d
: Counter reset value.
Range = 0000000001-
2000000000 (mandatory
10 characters).
*e
: Current repeat value.
Range = 0000000000-
0010000000 (mandatory
10 characters).
1C01CS0010010000000001000
00000010000000999\0
=
Counter number: 0
Count direction: Upwards
Fill zeros: Enabled
Counter steps: 1
Start value: 1
Current value: 1
Reset value: 999