(24)
EPT052026 Issue 1 February 2019
Set print direction
^1V01CS
*x
\0
*x
=0: Left to right normal.
*x
=1: Right to left normal.
*x
=2: Left to right inverted
*x
=3: Right to left inverted
^1V01CS0\0 = Left to right
normal.
^1V01CS1\0 = Right to left
normal.
^1V01CS2\0 = Left to right
inverted.
^1V01CS3\0 = Left to right
inverted.
Set print mode
^1W01CS*
x*y*z
*t
\0
*x
=0: Sensor mode.
*x
=1: Continuous mode.
*y
: Number of prints for each
time the sensor is triggered
(mandatory 3 characters).
This value is passed if using
continuous mode.
*z
: Space between prints, in
inches (mandatory 5
characters).
*t
:=0 Continuously print after
the product detect sensor is
triggered once.
*t
:=1 continuously print when
the product detect sensor is
continuously triggered. Stop
printing when the product
detect sensor is not
triggered.
^1W01CS0002003930\0 = Print
in sensor mode. Make 2 prints,
each time the sensor is
triggered. Set a 10cm space
between prints. Continuously
print after the product detect
sensor is triggered once.
Set print delay
time
^1D01CS
*x*y
\0
*x
= Delay before print, in
inches. Range = 00039-
39370 (mandatory 5
characters).
*y
= Delay after print, in
inches. Range = 00039-
39370 (mandatory 5
characters).
^1D01CS0019600393\0 = Set a
delay of 5cm before the print
and 10cm after the print.
Set sensor
^1H01CS
*x
\0
*x
=0: Use internal product
detect sensor.
*x
=1: Use external product
detect sensor.
^1H01CS0\0 = Use the internal
product detect sensor.
^1H01CS1\0 = Use an external
product detect sensor.
Table 2: PLC to Printer
Operation
Command
Parameter
Examples
Содержание G20I
Страница 1: ...Domino G20i RS485 Guide G20i...
Страница 2: ...2 EPT052026 Issue 1 February 2019 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 4: ...4 EPT052026 Issue 1 February 2019 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 6: ...6 EPT052026 Issue 1 February 2019 AMENDMENT RECORD Amendment Date All parts at Issue 1 February 2019...
Страница 36: ...36 EPT052026 Issue 1 February 2019 THIS PAGE INTENTIONALLY LEFT BLANK...