SECTION A. INSTALLATION

2. VENTILATION

The installation shall be made in such a manner as to
separate the combustion system from the living space of the
mobile home or recreational vehicle. Openings for air supply
or for venting of combustion products shall have a minimum
dimension of not less than 1/4 inch.

Proper installation requires one fresh air intake and one
upper exhaust vent. The ventilation kits shown in this
instruction manual have been certified for use with the
refrigerator model listed in the Table. For "Certified Vent
System Kits" see Section B. The ventilation kits must be
installed and used without modification. An opening toward
the outside at floor level in the refrigerator compartment must
be provided for ventilation of heavier-than-air fuel gases. The
lower vent of the recommended kits is provided with proper
size openings. The flow of combustion and ventilation air
must not be obstructed.

NOTEThe upper vent should be
centered over the condenser coil
at the back of the refrigerator.

FIG. 1

1. GENERAL INSTRUCTIONS

This appliance is designed for storage of foods and
storage of frozen foods and making ice.

The refrigerators outlined herein have been design certified
by A.G.A. under ANSI Z21.19 Refrigerator Standard for
installation in a mobile home or recreational vehicle and are
approved by the Canadian Gas Association.

The certifications are, however, contingent on the instal-

lation being made in accordance with the following instruc-
tions as applicable.

In the U.S.A., the installation must conform with:
1. National Fuel Gas Code ANSI Z223.1-(latest edition)
2. Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280
3. Recreational Vehicles ANSI A119.2-(latest edition).

The unit must be electrically grounded in accordance with
the National Electric Code ANSI/NFPA 70-(latest edition)
when installed if an external alternating current electrical
source is utilized.

4. Any applicable local code.

In Canada, the installation must conform with:
1. Current CGA B 149 Gas Installation Codes
2. Current CSA Standard Z 240.4 GAS-EQUIPPED REC-

REATIONAL VEHICLES AND MOBILE HOUSING

3. Any applicable local code
The unit must be electrically grounded in accordance with
the CANADIAN ELECTRICAL CODE C 22 Parts 1 and 2.

The lower side vent is fitted with a panel which provides an
adequate access opening for ready serviceability of the
burner and control manifold of the refrigerator. This should be
centered on the back of the refrigerator.

3. CERTIFIED INSTALLATION

Certified installations require one roof vent and one lower
side vent.

For certified vent system kits, see Section B.
For further information, contact your dealer or distributor.

4. METHOD OF INSTALLATION

The method of installation is shown in FIG. 1. It is essential
that all maximum or minimum dimensions are strictly main-
tained as the performance of the refrigerator is dependent on
adequate flow of air over the rear of the refrigerator.

Содержание RM7030

Страница 1: ...WARNING Improper installation adjustment alteration service or maintenance can cause injury or property dam age Refer to this manual For assis tance or additional information consult a qualified installer service agency or the gas supplier AVIS Cet appareil doit être réparé seulement par un réparateur autorisé Modification de l appareil pourrait être extrèmement dangeruse et pourrait causer mal ou...

Страница 2: ...owever contingentontheinstal lation being made in accordance with the following instruc tions as applicable In the U S A the installation must conform with 1 National Fuel Gas Code ANSI Z223 1 latest edition 2 ManufacturedHomeConstructionandSafetyStandard Title 24 CFR Part 3280 3 Recreational Vehicles ANSI A119 2 latest edition The unit must be electrically grounded in accordance with the National...

Страница 3: ...ator NOTE Clearance N isthedistancebetweenthebottom of the lower vent to the roof material For ventilation height refertoSectionA Installation Item5 Ventilation Heights See FIG 2 FIG 2 e Refrigerator Overall Installation Recess Model Dimensions Dimensions Dimensions RM7030 Height Width Depth Height Width Depth Height Width Depth A B C h w d H W D Inches 58 3 4 33 1 2 23 5 8 57 1 8 32 3 8 22 5 8 57...

Страница 4: ...he appliance s combustion system from the vehicle interior NOTE Becarefulnottodamagethesealingstripappliedto theflooroftheenclosurewhentherefrigeratorisputinplace The refrigerator is secured in the enclosure with six screws and they must be installed in the following order First Two Screws installed on front base Second Two Screws installed in the top frame Third Two Screws installed in the rear b...

Страница 5: ...le Cover Drain W ater Hose Flexible Cord FIG 6 When testing the gas supply system at test pressures in excess of 1 2 psig the refrigerator and its individual shutoff valve must be disconnected from the gas supply piping system When testing the gas supply system at pressures less than orequalto1 2psig theappliancemustbeisolatedfromthe gas supply piping by closing its individual manual shutoff valve...

Страница 6: ... PANEL The refrigerator is normally delivered without the door pan els Before starting the mounting work check that the panel dimensions are in compliance with those given in the Table on Page 7 and the instructions are read thoroughly When mounting the panel proceed as follows See FIG 8 NOTE If raised door panels are going to be used be 1 1 1 2 1 1 6 4 3 5 1 FIG 8 suretheconsumercanproperlyoperat...

Страница 7: ...ectionsoftheevaporator tubing This will slow the circulation of hydrogen and ammo nia gas or in severe cases completely block it resulting in a loss of cooling Any time the vehicle is parked for several hours with the refrigerator operating the vehicle should be leveled to pre ventthislossofcooling Thevehicleneedstobeleveledonly so it is comfortable to live in no noticeable sloping of floors or wa...

Страница 8: ...tor button 2 to the DOWN position If 120 volts AC is available the AC mode indicator lamp A will illuminate indicating AC operation If120voltsACisnotavailable theGASmode indicator lamp C will illuminate and the control system will automatically switch to GAS operation 2 IftheCHECKindicatorlamp D illuminatesandtheGAS mode indicator lamp C is off the controls have failed to ignite the burner in the ...

Страница 9: ... the frozen food storage compartment provided they are precooled first in the refrigerator They can be stored about three times longer in the frozen food compartment as compared to the fresh food compartment To prevent food and it then becomes unavailable the system will auto matically switch to GAS As soon as AC becomes availableagainthecontrolwillswitchbacktoACregard less of the status of GAS op...

Страница 10: ...rong chemicals or abrasives to clean these parts as the protective surfaces will be damaged It is important to always keep the refrigerator clean F SHUT OFF STORAGE PROCEDURE ShutofftherefrigeratorbypressingthemainpowerON OFF button to the UP OFF position Iftherefrigeratorwillnotbeinoperationforaperiodofweeks it should be emptied defrosted cleaned and the doors left ajar The ice tray should also b...

Страница 11: ...nder the freezer to ON The climate control can be left on continuously or only used when temperatures require it NOTE The climate control will draw 12 volts DC power continuously when in the ON position It should be turned OFF when a charging source is not available Most LP gas appliances used in recreational ve hiclesareventedtotheoutsideofthevehicle When parkedclosetoagasolinepump itispossibleth...

Страница 12: ...wer start stop the engine etc Compare the operation with the operation described in Section C Operation Instructions F FUSES The 2 way AES model is equipped with 2 fuses one for the refrigerator control system and one for the AC cartridge heater See Table below To replace fuse s proceed as follows 1 Disconnect the wall plug and the 12 volt wires 2 Remove the power module cover See FIG 6 3 Snap the...

Страница 13: ...operly before starting the ice maker The refrigerator has to be connected to120voltsACbeforetheicemakercanoperate Thewater line manual shutoff valve must be open To start the ice making move the ice level bail arm to down position see FIG 12 To shut off the ice making move the ice level bail arm to fully up position see FIG 12 Whentheicemakerthermostatsensesthepresettempera tureforejectionoftheice...

Страница 14: ...E 5A FUSE 3A SWITCH HEATING CA BLE R Q M LIGHT U RETAINER F OR TERMINAL BL OCK TERMINAL BL OCK S T CIRCUIT BOA RD P OWER 5 6 GREY BROWN 7 BLUE GREEN GREEN YELLOW 3 4 BLACK WHITE 2 1 Q 6 TROUBLESHOOTING Ice Maker Fails Does Not Make Ice A Check fuses or breaker supplying 120 volts AC to refrigerator and check that RV is connected to power B Check that ice level bail arm is in down position C Check ...

Отзывы: