DIAGNOSTIC SERVICE MANUAL

DIAGNOSTIC SERVICE MANUAL

DIAGNOSTIC SERVICE MANUAL

DIAGNOSTIC SERVICE MANUAL

DIAGNOSTIC SERVICE MANUAL

Dometic

Dometic

Dometic

Dometic

Dometic

®  

®  

®  

®  

®  

RM3604/3804 AES

RM3604/3804 AES

RM3604/3804 AES

RM3604/3804 AES

RM3604/3804 AES

®

®

®

®

®

Refrigerators

Refrigerators

Refrigerators

Refrigerators

Refrigerators

BROWN

ORANGE

10 Pin

7 Pin

YELLOW

BROWN

10 Pin

7 Pin

BROWN

10 Pin

7 Pin

GREEN

With the mode switch (?) manually depressed

With the mode switch (?) manually depressed

With the mode switch (?) manually depressed

With the mode switch (?) manually depressed

With the mode switch (?) manually depressed:
An ohms reading should be
indicated between the brown
terminal on the 10-pin connector
(negative[–] lead from meter) to
the orange terminal on the 7-pin
connector (positive [+] lead from
meter). The ohms reading should
be approximately 26,000. You
should NOT

NOT

NOT

NOT

NOT have a reading unless the mode switch

(?) is depressed.

NOTE

NOTE

NOTE

NOTE

NOTE: If the check on 12-volt mode lamp and switch
is not correct, verify the wire harness has continuity.
If wire harness is good, replace the upper circuit
board.

10. Delay Mode Lamp and Switch

Delay Mode Lamp and Switch

Delay Mode Lamp and Switch

Delay Mode Lamp and Switch

Delay Mode Lamp and Switch

NOTE

NOTE

NOTE

NOTE

NOTE: The following checks should be made on the
upper circuit board and harness assembly BEFORE
replacing the upper circuit board or wiring harness.
The checks are to be done with the wiring harness
REMOVED from the lower circuit board, and the
OFF-ON switch turned to "ON".

With the mode switch (?) manually depressed

With the mode switch (?) manually depressed

With the mode switch (?) manually depressed

With the mode switch (?) manually depressed

With the mode switch (?) manually depressed:
Resistance should be indicated between the brown
terminal on the 10-pin connector (negative [–] lead
from meter) to the yellow termi-
nal on the 7-pin connector
(positive [+] lead from meter).
The proper resistance is approxi-
mately 26,000 ohms.

With the mode switch (?) NOT

With the mode switch (?) NOT

With the mode switch (?) NOT

With the mode switch (?) NOT

With the mode switch (?) NOT
depressed

depressed

depressed

depressed

depressed: A reading would
NOT

NOT

NOT

NOT

NOT be indicated.

NOTE

NOTE

NOTE

NOTE

NOTE: If the check on the delay mode lamp and
switch is not correct, verify the wire harness has
continuity. If wire harness is good, replace the upper
circuit board.

11.  Gas Mode Lamp and Switch

Gas Mode Lamp and Switch

Gas Mode Lamp and Switch

Gas Mode Lamp and Switch

Gas Mode Lamp and Switch:

NOTE: The following checks should be made on the
upper circuit board and harness assembly BEFORE
replacing the upper circuit board or wiring harness.
The checks are to be done with the wiring harness
REMOVED from the lower circuit board, and the ON-
OFF switch turned to "ON".

With the mode switch (?) manually depressed

With the mode switch (?) manually depressed

With the mode switch (?) manually depressed

With the mode switch (?) manually depressed

With the mode switch (?) manually depressed:
Resistance should be indicated
between the brown terminal on
the 10-pin connector  (negative [–
] lead from meter) to the green
terminal on the 7-pin connector
(positive [+] lead from meter).
The proper resistance is approxi-
mately 26,000 ohms.

With the mode switch (?) NOT depressed

With the mode switch (?) NOT depressed

With the mode switch (?) NOT depressed

With the mode switch (?) NOT depressed

With the mode switch (?) NOT depressed:  A
reading would NOT

NOT

NOT

NOT

NOT be indicated.

NOTE

NOTE

NOTE

NOTE

NOTE:  If the check on gas mode lamp and switch is
not correct, verify the wire harness has continuity. If
wire harness is good, replace the upper circuit board.

12.  Gas Flame Warning Lamp

Gas Flame Warning Lamp

Gas Flame Warning Lamp

Gas Flame Warning Lamp

Gas Flame Warning Lamp:

NOTE: The following checks should be made on the
upper circuit board and harness assembly BEFORE
replacing the upper circuit board or wiring harness.
The checks are to be done with the wiring harness
REMOVED from the lower circuit board,
and the OFF-ON switch turned to "ON".

Measure resistance between the brown
terminal on the 10-pin connector (nega-
tive [–] lead from meter) to the black
terminal on the 10-pin connector (positive
[+] lead from meter). The proper resis-
tance is approximately 22,000 ohms.

NOTE

NOTE

NOTE

NOTE

NOTE: If the check on gas flame warning
lamp is not correct, verify the wire harness has
continuity. If wire harness is good, replace the upper
circuit board.

4.10

4.10

4.10

4.10

4.10 CIRCUIT BOARD

CIRCUIT BOARD

CIRCUIT BOARD

CIRCUIT BOARD

CIRCUIT BOARD

The circuit board controls all modes of operation.

1.

THESE PROCEDURES MUST BE FOLLOWED
IN SEQUENCE AND AT THE PROPER TERMI-
NALS OR DAMAGE TO THE BOARD WILL
RESULT.

Before any checks are to be done, be sure proper
DC volts are to the board (see Sec.
3.1). Measure volts between yellow
terminal on the 6-pin connector (posi-
tive [+] lead from meter) to green
terminal on 6-pin connector (negative [–
] lead from meter). Voltage should be
the same as at the positive (+) and
negative (–) terminal block. If not,
check the fuse (see Sec. 4.11) and
wiring (see Sec. 7.2).

2.

THESE PROCEDURES MUST BE FOLLOWED
IN SEQUENCE AND AT THE PROPER TERMI-
NALS OR DAMAGE TO THE BOARD WILL
RESULT.

BLACK

BROWN

10 Pin

YELLOW

GREEN

6 P IN 

Содержание RM3604

Страница 1: ...Foreword Foreword This service manual is the result of the dedication of The Dometic Corporation and its engineers in giving service people the necessary instruction for making accurate analyses of c...

Страница 2: ...it Board Switch Card 4 1 1 Fuse 9 SECTION 5 LP GAS REQUIREMENTS _ _ 10 SECTION 6 LP GAS COMPONENTS 6 1 Manual Shut Off Valve _ _ _ _ 10 6 2 Orifice 10 6 3 Thermocouple ___ _ _ __ __ _ _ 10 6 4 Burner...

Страница 3: ...Upper Circuit Board 4 9 2 12 Circuit Board 4 10 5 AC Volts 1 Heating Element 2 Upper Circuit Board 4 9 2 5 Wiring 7 2 Thermostat 4 2 Circuit Board 4 10 2 DC Volts 3 1 Heating Element 4 1 Upper Circuit...

Страница 4: ...14 Flame failure light after 3 minutes 15 Interior Light ON when door is closed 16 Rapid formation of frost AC Volts 1 Heating Element 2 DC Volts 3 Heating Element 4 1 Wiring 7 2 LP gas 5 1 Orifice 6...

Страница 5: ...Maximum fuse size 25 amp for RM3604 and RM3804 3 PRONG PLUG FOR 120V AC FUSE LINK 3AMP MANUAL GAS SHUTOFF VALVE IGN LOCK COVER TERMINAL BLOCK With the refrigerator operating on AC or gas mode if volta...

Страница 6: ...With the igniter producing spark connect meter leads to L and ground terminals on the igniter with the meter set on 20 volts DC range or lower The meter should read a pulsating voltage If not replace...

Страница 7: ...ld be off When the refrigerator door is open the switch is closed interior light should be on Check that the switch assembly is properly aligned and that it is not broken Check the switch assembly for...

Страница 8: ...turned to ON With the AES function switch manually With the AES function switch manually With the AES function switch manually With the AES function switch manually With the AES function switch manual...

Страница 9: ...ion switch With the gas function switch With the gas function switch With the gas function switch With the gas function switch NOT depressed NOT depressed NOT depressed NOT depressed NOT depressed A r...

Страница 10: ...amp and Switch NOTE The following checks should be made on the upper circuit board and harness assembly BEFORE replacing the upper circuit board or wiring harness The checks are to be done with the wi...

Страница 11: ...from meter If no voltage is present replace the circuit board If voltage is present the circuit board is NOT defective do not replace BLACK 6 Pin RED 6 Pin 4 THESE PROCEDURES MUST BE FOLLOWED IN SEQUE...

Страница 12: ...for a few moments while depressing the safety valve Remove the flame and release the safety valve The valve should hold for at least 30 seconds If it does not hold the safety valve open for 30 second...

Страница 13: ...te capacity to avoid voltage drop The wire gauge should be chosen with consideration to the wire length in accordance with the Table below MAXIMUM CONDUCTOR WIRE LENGTH IN FEET MAXIMUM CONDUCTOR WIRE...

Страница 14: ...F CIRCUIT BOARD TERMINALBLOCK HEATER CONNECTOR MAIN SWITCH DOOR SWITCH LIGHT THERMOSTAT GAS VALVE COIL THERMOCOUPLE REIGNITER TIME FUSE 3 3 15 AMP GAS FLAME WARN LAMP GAS FUNCTION SWITCH GAS FUNCTION...

Страница 15: ...eve proper air flow All potential dead air pockets should be blocked or baffled to insure that heat won t be trapped in these spaces and reduce efficiency In addition the cooling unit should be at lea...

Страница 16: ...tainers of water Next supply 115 volts direct to the AC heating element and operate for at least 12 hours Then check the temperature on the thermometer It should be at 45 degrees or lower depending on...

Отзывы: