a year, but should only be done by a qualified serviceman
who is familiar with LP gas systems and refrigerators.

D. The LP gas pressure should be checked and the main

regulator readjusted if pressure is incorrect. The correct
operating pressure is 11 inches of water column. The
correct place to take the LP gas pressure is at the test
port just ahead of the burner jet. (See FIG. 11).

E. Inspect the flue baffle. It should be reasonably clean and

free of soot. Heavy soot formation indicates improper
functioning of the burner. The flue and burner both require
cleaning in the following manner:
1) Unplug the refrigerator power cord from the 120 volt

AC outlet (see FIG. 6).

2) Disconnect or shut off the 12 volt power to the

refrigerator.

3) Turn manual shutoff valve to OFF. (See FIG. 6 & 11).
4) Remove cover from the burner housing. (See FIG . 6).
5) Disconnect the wire from the high voltage electrode.
6) Remove the burner mounting screws and remove the

burner assembly.

7) Remove the flue cap from top of flue tube and lift out

the wire and spiral baffle. Clean the flue from the top
using a flue brush. Blowing compressed air into the
flue will not properly clean soot and scale out of the
flue tube. Replace spiral baffle and flue cap.

8) Clean burner tube with a brush. Blow out burner with

compressed air.

9) Before removing burner jet, clean burner area of soot

and scale that fell out of flue tube. Remove the burner
jet. Soak the jet in wood alcohol and blow it out with
compressed air. Reinstall and tighten burner jet.

DO NOT use a wire or pin when cleaning the burner jet
as damage can occur to the precision opening. This can
cause damage to the refrigerator or create a fire hazard.

10) Reinstall  burner, being careful that the end of the

burner fits into the slot on the burner bracket. Check
to make sure slots are centered under the flue tube
and the thermocouple is positioned properly (tip of
thermocouple extends over two slots of burner).

11) Be sure to reconnect the wire to high voltage elec-

trode. Check the electrode for proper location and
gap. (See FIG. 12).

                      

ELECTRODE

BURNER T UBE

1/8" T O 3/16"
(3-5 mm)

12) Turn on manual gas shutoff valve and check all

fittings for leaks.

13) Connect 120 volt power cord to the outlet and

reconnect or turn on the 12 volt DC power.

14) Check LP gas safety shutoff. See 

Section A. Instal-

lation, Item 9. Testing LP Gas Safety Shutoff.

GAS EQUIPMENT ASSEMBLY

FIG. 11

MANUAL SHUT-OFF VALVE
Shown in open position
Use a quarter dollar or a slotted  srewdriver
to change position

SOLENOID VALVE

BURNER  MOUNTING  SCREWS

THERMOCOUPLE

BURNER
TUBE

SPARK
ELECTRODE

BURNER
JET

PRESSURE T EST
PORT

INLET FITTING

FIG. 12

Содержание RM2607

Страница 1: ...OR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintena...

Страница 2: ...e however contingent on the installa tionbeingmadeinaccordancewiththefollowinginstructions as applicable In the U S A the installation must conform with 1 National Fuel Gas Code ANSI Z223 1 latest edi...

Страница 3: ...ator and the wall behind the refrigerator NOTE Clearance N isthedistancebetweenthebottom of the lower vent to the roof material For ventilation height refertoSectionA Installation Item5 Ventilation He...

Страница 4: ...equence in securing refrigerator in enclosure can cause leakage between the frame and cabi net The plastic caps are snapped in the front base to cover the screw heads and the decoration strip is secur...

Страница 5: ...oceeding Be careful not to damage burner jet Replace cover and turn the main switch OFF and back ON See Section C Operation Instructions Item2 ControlPanel Normaloperationof the burner should return A...

Страница 6: ...nded wire sizes are shown below MAXIMUM TOTAL CONDUCTOR WIRE LENGTH In Feet and Meters RM RM AWG 2607 2807 215W 215W 10 17 FT 17 FT 5 M 5 M 8 27 FT 27 FT 8 M 8 M Thewiresfromthebatterytotherefrigerato...

Страница 7: ...Plastic caps for the empty holes are in the parts bag Remountthedoorsandthehingepinsinthereverseorderof theirremoval Unscrewthehandlesandrefastenthemonthe opposite side of the door Insert the plastic...

Страница 8: ...be leveled only so it is comfortable to live in no noticeable sloping of floors or walls When the vehicle is moving the leveling is not critical as the rolling and pitching motion of the vehicle will...

Страница 9: ...o the OFF then ON position If the control is switched to AC operation while the CHECK indicator lamp is on it will function properly but the CHECK indicator lamp will not go off until the main power O...

Страница 10: ...n ON position If the control is switched to AC or DC operation while the CHECK indicator lamp is on it will function properly but the CHECK indicator lamp will not go off until the main power ON OFF b...

Страница 11: ...d in direct contact with the freezer shelf Toreleasetheicecubes seizethetraywithbothhandsand twist the tray Cubes not required should be replaced in the tray Refill the tray with water and replace the...

Страница 12: ...per vent and area between these openings for any obstructions such as bird insect nests spider webs etc Clean the coils on the back of the refrigerator Use a soft bristled brush to dust off the coils...

Страница 13: ...lue cap 8 Clean burner tube with a brush Blow out burner with compressedair 9 Beforeremovingburnerjet cleanburnerareaofsoot andscalethatfelloutoffluetube Removetheburner jet Soak the jet in wood alcoh...

Страница 14: ...rized service center for parts and repairs as needed F FUSES The2 wayAMESmodelsareequippedwith2fuses onefor the refrigerator control system and one for the AC cartridge heater The 3 way AMES models ar...

Отзывы: