Hook-up to the gas supply line is accomplished at the manual gas shutoff valve,
which is furnished with a 3/8" SAE (UNF 5/8" - 18) male flare connection. Always use
a backup wrench when connecting the gas supply line to the gas inlet fitting.
Gas connection may only be carried out by a qualified personnel.
25
Following proper installation, a testing for leakage and a flame test must be car-
ried out by *qualified personnel. A certificate of testing must be issued.
* qualified personnel
Qualified personnel are accredited experts who are able, by virtue of their training and knowledge,
to vouch for the correct implementation of the leakage test.
Gas supply
LP GAS
CYLINDER
PRESSURE
REGULATOR
TO
REFRIGERATOR
The gas supply system must incorporate a pressure regulator to maintain a supply pres-
sure of not more than 13.5 inches water column, static (no load).When testing the gas
supply system at test pressures in excess of 1/2 psig, the refrigerator and its individual
shutoff valve must be disconnected from the gas supply piping system.When testing the
gas supply system at pressures less than or equal to 1/2 psig, the appliance must be
isolated from the gas supply piping by closing its individual manual shutoff valve.In case
detailed instructions on the installation and connection to the gas supply are required,
contact your dealer or distributor.
Check all connections for gas leaks with soap and water. DO NOT use a naked
flame for detecting leaks. Ignite the burner to ensure correct operation of gas
valve, burner and ignition. In case the appliance fails to operate correctly after
all checks have been carried out, refer to the authorised service provider in your
area.
Gas pressure
Refer to data label.
The refrigerator must be
equipped with a gas cock in
the supply line to allow the
supply to be disconnected.
Such a cut-out device must
be readily accessible to the
user.
20 Nm
max
10 Nm
max
Test point
Gas burner
Connection
of gas supply
SW 14
SW 17
RM 7401 L
RM 7551 L
WARNING
WARNING