background image

9

THERMOSTAT

The thermostat on the refrigerator controls both the gas

and electric operation, thereby eliminating the neces-

sity of resetting each time a different energy source is

employed.

After the initial start-up, the thermostat should be moved

from  “COLDEST”  to  the  desired  temperature  setting,

usually at mid setting.

TO SHUT OFF THE REFRIGERATOR

The refrigerator may be shut off while in any mode of

operation by pressing the main power ON/OFF button

to the UP (OFF) position. This shuts off all DC power to

the refrigerator, including the interior light.

START UP INSTRUCTIONS

A. A continuous 12 volt DC supply must be available

for the electronic control to function.

B. Press  the  main  power  ON/OFF  button  (1)  to  the

DOWN position.

C. Press the TEMPERATURE SELECTOR button (3)

until the lamp at the desired setting is illuminated.

AES/AUTO MODE

1. Press the AES/AUTO/GAS mode selector button (2)

to turn ON the AES/AUTO lamp (B). If 120 volts is

available, the AC mode indicator lamp (A) will illumi-

nate indicating AC operation. If 120 volts AC is not

available, the GAS indicator lamp (C) will illuminate

indicating the control has automatically switched to

the GAS mode.

2. If the CHECK indicator lamp (D) illuminates and the

GAS mode indicator lamp (C) is off, the controls have

failed to ignite the burner in the GAS mode. GAS

operation may be reset by pressing the main power

ON/OFF button (1) to the OFF then ON position. (See

step 2 under GAS MODE).

3. Press the TEMPERATURE SELECTOR button (3)

until the lamp at the desired position is illuminated.

GAS MODE

1. Press the AES/AUTO/GAS mode selector button (2)

to turn OFF the AES/AUTO lamp (B). The GAS mode

indicator lamp (C) will illuminate. Within 45 seconds

the burner should be ignited and operating normally.

2. On the initial refrigerator start-up, it may take longer

than 45 seconds to allow air to be purged from the

gas line. If the gas does not ignite within 45 seconds

the CHECK indicator lamp (D) will illuminate and the

GAS mode indicator lamp (C) will go off.
To reset when the CHECK indicator lamp (D) is illu-

minated, press the main power ON/OFF button (1)

to the OFF and then ON position.

NOTE:

 Do not continue to reset GAS operation if the

CHECK indicator lamp continues to be illuminated

after several tries.

3. Press the TEMPERATURE SELECTOR button (3)

until the lamp at the desired position is illuminated.

ON

OFF

AC

GAS

CHECK

AES

AUTO

COLD

1

2

3

4

5 COLDEST

CLC

LAC

DISPLAY PANEL

B

A

D

C

E

F

G

1

2

3

4

5

Содержание NDR1492-B

Страница 1: ...stance or additional information consult a qualified installer service agency or the gas supplier AVIS Cet appareil doit tre r par seulement par un r parateur autoris Modification de l appareil pourra...

Страница 2: ......

Страница 3: ...or Button 4 Climate Control Button 5 Low Ambient Control Button A AC Mode Indicator Lamp B AES AUTO Mode Indicator Lamp C GAS Mode Indicator Lamp D CHECK Indicator Lamp E Temperature Indicator Lamps F...

Страница 4: ...led and used without modification An opening toward the outside at floor level in the refrigera tor compartment must be provided for ventilation of heavier than air fuel gases The lower vent of the re...

Страница 5: ...be sealed Make sure that there is a complete seal between the front frame of the refrigerator and the top sides and bottom of the enclosure A length of sealing strip is ap plied to the rear surface o...

Страница 6: ...as safety shutoff must be tested after the re frigerator is connected to LP gas supply To test the gas safety shutoff proceed as follows 1 Start the refrigerator according to the instructions and swit...

Страница 7: ...r coil at the back of the refrigerator VENTILATION HEIGHTS CLEARANCES Minimum clearances in inches to combustible materials are G Top 0 K Side 0 L Bottom 0 M Rear 0 N See NOTE Clearance N below NOTE C...

Страница 8: ...f the vehicle will pass to either side of level keeping the liquid ammonia from accumulating in the evaporator tubing OPERATION Before starting the refrigerator check that all the manual gas valves ar...

Страница 9: ...as automatically switched to the GAS mode 2 If the CHECK indicator lamp D illuminates and the GAS mode indicator lamp C is off the controls have failed to ignite the burner in the GAS mode GAS operati...

Страница 10: ...imes If repeated attempts fail to start the LP gas operation check to make sure that the LP gas supply tanks are not empty and all manual shutoff valves in the lines are open If the problem is still n...

Страница 11: ...he ice is formed Food in the fresh food compartment may be frozen if the setting is left on COLDEST posi tion DEFROSTING Shut off the refrigerator by pressing the main power ON OFF button to the UP OF...

Страница 12: ...ar with LP gas systems and refrigerators 1 REFRIGERATOR REMOVAL Before working on the refrigerator make sure the AC voltage and DC voltage leads are disconnected Shut off the gas supply Disconnect the...

Страница 13: ...ea of soot and scale that fell out of flue tube Remove the burner jet Soak the jet in wood alcohol and blow it out with compressed air Reinstall and tighten burner jet NOTE The color of the flame shal...

Страница 14: ...e not responsible for any failures caused by improper adjust ments and unfavorable installation conditions Contact service point or distributor service dept for assistance Replacement Parts Suppliers...

Страница 15: ...e of the shelf will come loose Lower the right hand side of the wire shelf and let the left hand side slide out of the holes in the wall Slide the plastic plugs into the holes of the wall Snap the she...

Страница 16: ...16 MO FO 0222...

Отзывы: