35
EN
Frigo DC
Connecting the transport refrigeration system
➤
Route the condensation hose along the refrigerant hoses to the evaporator.
➤
Guide the condensation hose outside through the base of the vehicle, so that
the condensate is discharged.
➤
Connect the fan and the temperature sensor in accordance with the circuit
diagram (fig.
, page 10 and supplementary sheet).
I
➤
Attach the cover
–
with 4 x bolts for Frigo DC 2500 or
–
with 6 x bolts for Frigo DC 3500.
➤
Connect the condensation hose to the cover with the hose clamp 10 – 16
(fig.
➤
Attach the sticker.
9.5.4
Connecting cables to the DC unit
➤
Route the refrigerant hoses under the vehicle to the DC unit.
➤
Route the extension cable under the vehicle to the DC unit.
➤
Connect the refrigerant hoses.
➤
Connect the extension cable.
➤
Route the connection cable of the DC unit to the vehicle’s battery.
9.5.5
Connecting the transport refrigeration system to the battery
➤
Connect the connection cable for the DC unit to the battery in accordance
with the circuit diagram (fig.
tary sheet).
➤
Mount the fuse supports as illustrated (fig.
➤
Connect the earth connections to the vehicle chassis.
NOTE
Ensure that the connection cables are inside the cover when installing the
evaporator cover.
Frigo_DC-I-West.book Seite 35 Mittwoch, 24. Juni 2020 11:27 11
Содержание Frigo DC 2500
Страница 7: ...Frigo DC 6 9 P 1 2 3 4 76 35 56 3 28 0 Frigo_DC I West book Seite 6 Mittwoch 24 Juni 2020 11 27 11...
Страница 9: ...Frigo DC 8 A C D E F G B d Frigo_DC I West book Seite 8 Mittwoch 24 Juni 2020 11 27 11...
Страница 12: ...11 Frigo DC h 80 mm i Frigo_DC I West book Seite 11 Mittwoch 24 Juni 2020 11 27 11...
Страница 13: ...Frigo DC 12 2 1 j 2 3 1 4 k Frigo_DC I West book Seite 12 Mittwoch 24 Juni 2020 11 27 11...
Страница 14: ...13 Frigo DC Frigo DC 3500 Frigo DC 2500 l m Frigo_DC I West book Seite 13 Mittwoch 24 Juni 2020 11 27 11...
Страница 15: ...Frigo DC 14 A B n 2 3 1 o Frigo_DC I West book Seite 14 Mittwoch 24 Juni 2020 11 27 11...