Understand Signal Words
DuraSea Rooftop Installation & Operations Manual
2
L-3075 ENGLISH
4.
Condensation Note:
The manufacturer of this unit is not responsible for damage caused by condensation forming on
ceilings, windows, or other surfaces. Air contains water vapor which condenses when the temperature of a surface is
below the Dew point. During normal operation this unit is designed to remove a certain amount of moisture from the air,
depending on the size of the space being conditioned. Keeping doors and windows closed when this air conditioner is
in operation will greatly reduce the chance of condensation forming on interior surfaces.
Specifications
Table 1: Product Specifications
Model
115 VAC/60 Hz
Nominal Capacity (BTU/hr) Cooling
15,000
Electrical Rating
120 VAC - 60 Hz - 1 Phase
Running Amps
15.3
Compressor Locked Rotor Amps
66.0
Fan Motor Locked Rotor Amps
5.8
Refrigerant Type
R-410A
Minimum Wire Size*
12 AWG Copper up to 24 feet (7.31 m)
Minimum Generator Size** 1 Unit / 2 Units
3.5 KW / 5.0 KW
AC Circuit Protection*** Installer Supplied
20 Amp
Rating Plate
3311983.000
Height (in/mm)
13.125 / 334
Width (in/mm)
29.875 / 759
Depth (in/mm)
34.875 / 886
Weight (lbs/kg)
103 / 46.7
*
**
***
For wire length over 24 feet (7.31 m), consult the National Electric Code for proper sizing.
Dometic Marine gives GENERAL guidelines for generator requirements. To reduce start-up power draw by up to
65%, consider installing a Dometic SmartStart.
Circuit Protection: Time Delay Fuse or Circuit Breaker required