![Dometic DuraSea Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/dometic/durasea/durasea_installation-and-operation-manual_2518230010.webp)
Installing The Unit
DuraSea Rooftop Installation & Operations Manual
8
L-3075 ENGLISH
7.
Measure the ceiling to roof thickness:
a.
If distance is 1" to 2" or 25 to 51 mm, remove perforated tabs from both upper and lower ducts. See Figure 7 and
Figure 8.
b.
If distance is 2" to 3" or 51 to 76 mm, remove perforated tabs from bottom duct only. See Figure 8.
c.
If distance is 3" to 4" or 76 to 102 mm, install ducts as received. See Figure 8.
d.
If distance is 4" to 6" or 102 to 153 mm, use optional duct adapter, part number 3106775.004 and bolt kit, part
number 3100895.006.
Figure 8: Ceiling Thickness Distance
8.
Install ceiling template by sliding lower duct over upper duct.
9.
Hold the ceiling template up to the 14.25" x 14.25" (± 1/8") or 362 x 362 mm (±3 mm) opening.
•
Start each mounting bolt through the ceiling template and up into the base pan by hand. See Figure 9.
•
Tighten all 4 bolts until they touch the template but are not tight.
•
With the ceiling template flat against the ceiling, install the 6 wood screws at an angle, so as to stretch and flatten
the template, using 3 across the front and 3 across the back of the template. See Figure 10.
•
EVENLY tighten the four bolts to a torque of 40 to 50 inch pounds. This will compress the roof gasket to
approximately 1/2" or 13 mm. The bolts are self locking so further tightening is not necessary. See Figure 9.
NOTE:
PROPERTY DAMAGE HAZARD. If bolts are left loose there may not be an adequate roof seal or if over tightened,
damage may occur to the unit base or ceiling template. Tighten to torque specifications listed in this manual.