Dometic DuraSea Скачать руководство пользователя страница 10

Installing The Unit

 

 DuraSea Rooftop Installation & Operations Manual

8

L-3075 ENGLISH

7.

Measure the ceiling to roof thickness:

a.

If distance is 1" to 2" or 25 to 51 mm, remove perforated tabs from both upper and lower ducts. See Figure 7 and 
Figure 8.

b.

If distance is 2" to 3" or 51 to 76 mm, remove perforated tabs from bottom duct only. See Figure 8.

c.

If distance is 3" to 4" or 76 to 102 mm, install ducts as received. See Figure 8.

d.

If distance is 4" to 6" or 102 to 153 mm, use optional duct adapter, part number 3106775.004 and bolt kit, part 
number 3100895.006.

Figure 8: Ceiling Thickness Distance

8.

Install ceiling template by sliding lower duct over upper duct.

9.

Hold the ceiling template up to the 14.25" x 14.25" (± 1/8") or 362 x 362 mm (±3 mm) opening.

Start each mounting bolt through the ceiling template and up into the base pan by hand. See Figure 9.

Tighten all 4 bolts until they touch the template but are not tight.

With the ceiling template flat against the ceiling, install the 6 wood screws at an angle, so as to stretch and flatten 
the template, using 3 across the front and 3 across the back of the template. See Figure 10.

EVENLY tighten the four bolts to a torque of 40 to 50 inch pounds. This will compress the roof gasket to 
approximately 1/2" or 13 mm. The bolts are self locking so further tightening is not necessary. See Figure 9.

NOTE:

PROPERTY DAMAGE HAZARD. If bolts are left loose there may not be an adequate roof seal or if over tightened, 
damage may occur to the unit base or ceiling template. Tighten to torque specifications listed in this manual.

Содержание DuraSea

Страница 1: ...Group Every precaution has been taken in the preparation of this manual to ensure its accuracy However Dometic Group assumes no responsibility for errors and omission Neither is any liability assumed...

Страница 2: ...UNIT ON THE ROOF 6 INSTALLING THE UNIT 6 WIRING SYSTEM TO POWER SUPPLY CONNECTION 9 AIR DISTRIBUTION BOX INSTALLATION 10 Operating Instructions 11 CONTROLS 11 OFF Position 11 Cooling Operation 12 Heat...

Страница 3: ...can support 130 pounds 59 kg of weight when the boat is in motion If applicable Roof construction with rafters joists on minimum of 16 inch 40 64 cm centers Minimum of 1 inch 2 54 cm and maximum of 4...

Страница 4: ...faces Specifications Table 1 Product Specifications Model 115 VAC 60 Hz Nominal Capacity BTU hr Cooling 15 000 Electrical Rating 120 VAC 60 Hz 1 Phase Running Amps 15 3 Compressor Locked Rotor Amps 66...

Страница 5: ...determining your cooling requirements the following should be considered Size of boat Window area increases heat gain Amount of insulation in walls and roof Geographical location where the boat will...

Страница 6: ...requirement Check inside the boat s cabin for obstructions to the air distribution box i e space for doors to open room dividers curtains ceiling fixtures etc See Figure 2 Figure 2 Interior Dimension...

Страница 7: ...359 mm it must be enlarged to 14 25 x 14 25 1 8 or 362 x 362 mm 3 mm NEW OPENING INSTALLATION OTHER THAN VENT OPENING 1 Mark a 14 25 x 14 25 1 8 or 362 x 362 mm 3 mm square on the roof and carefully...

Страница 8: ...rdered separately inside the boat This box contains mounting hardware for the unit and will be used inside the boat 3 Place the unit on the roof 4 Lift and place the unit over the prepared opening usi...

Страница 9: ...over blower discharge See Figure 6 Note Edges without flanges install toward REAR and SIDE of opening See Figure 6 Figure 6 Align Distribution Box s Upper Duct With Blower Discharge 5 Use two 2 10 x...

Страница 10: ...mplate up to the 14 25 x 14 25 1 8 or 362 x 362 mm 3 mm opening Start each mounting bolt through the ceiling template and up into the base pan by hand See Figure 9 Tighten all 4 bolts until they touch...

Страница 11: ...ground screw Tighten connector making sure not to damage wires 3 Connect white to white black to black using approved connectors Connect the bare copper wire to the ground screw located in the juncti...

Страница 12: ...ole plug into place at rear of air distribution box See Figure 14 4 There are four optional mounting holes on the outer edge of the return air opening for which screws are not provided These are only...

Страница 13: ...structions CONTROLS 1 The Selector Switch has 8 positions including OFF This controls fan speed heating mode optional and cooling modes See Figure 15 2 The Thermostat controls the temperature range at...

Страница 14: ...e air in your boat without cooling or heating There are three positions HIGH FAN MED FAN or LOW FAN to select from depending upon personal choice Maintenance AIR FILTER Periodically a minimum of every...

Страница 15: ...the manufacturer or its service agent or a similarly qualified person 4 When calling for service always give the following Unit type and serial number found on the identification label located on bas...

Страница 16: ...Frost Formation On Cooling Coil DuraSea Rooftop Installation Operations Manual 14 L 3075 ENGLISH Wiring Diagrams Figure 16 Unit Wiring Diagram Figure 17 Air Distribution Box Wiring Diagram...

Страница 17: ...liability or expense except as is specifically authorized and provided in this section Dometic reserves the right to improve its products through changes in design or material without being obligated...

Страница 18: ...and the date it is put in service In such instances the date of manufacture could indicate that the item is out of warranty However based on the date the equipment is first put in service the item ma...

Страница 19: ...ginal owner s warranty based on the original date of purchase or date of installation 2 Proof of purchase or installation may be required to verify warranty coverage 3 Any unit or replacement part ins...

Страница 20: ......

Отзывы: