Section III - Coverage Period

 

 DuraSea Rooftop Installation & Operations Manual

16

L-3075 ENGLISH

13. UV light bulbs are not covered.

14. Liquid line filter dryers are not covered.

15. Blowers with water damage.

16. Logic boards with water damage.

17. Logic boards with blown MOV's (Power Surge)

18. Mis-programmed displays.

19. Display heads with water damage.

20. Dirty Condensers and/or Evaporators.

21. Failures due to improper winterization.

22. Unit damage as a result of improper return packaging.

23. Replacement of freon with substitute without authorization from factory.

24. Environmental and/or Recovery Fees.

25. Welding and Nitrogen Fees.

26. Travel costs are included in the hourly labor allowances and should not be billed as a separate item without 

preapproval form the factory.

Installation and application of Dometic components is not warranted by Dometic, because Dometic has no control or 
authority over the selection, location, application, or installation of these components.

S

ECTION

 III - C

OVERAGE

 P

ERIOD

What is the period of coverage?

(See 

Limited

 

Warranty Periods 

at the end of this book).

All Dometic components bear a data plate on which there are model and serial numbers. The serial number is date coded. To 
determine whether or not any Dometic component is in warranty, proceed as follows:

1.

Determine the manufacture date of the component from the serial number on the data plate. If you are not familiar with 
the date code, write or call the Dometic Customer Service Department to obtain the manufacture date. The hours of 
the Customer Service Department are 8:00 a.m. - 5:00 p.m. (USA, Eastern Standard Time Zone) Monday through 
Friday excluding holidays.

2.

It is possible that there might exist a considerable time lag between the date a component is manufactured and the 
date it is put in service. In such instances, the date of manufacture could indicate that the item is out of warranty. 
However, based on the date the equipment is first put in service, the item may still be covered by the Dometic warranty 
as described in 

Section I

. For proof of date put in service, Dometic will require a copy of the bill of sale of the Dometic 

equipment from the installer or new boat dealer to the original owner. 

S

ECTION

 IV - G

ETTING

 S

ERVICE

How do you get service? 

Please read the following Warranty Procedure:

If the failure of a Dometic component is determined to be covered under the Dometic warranty and the time in service is 
determined to be within the warranty time limit, the owner has the following three options: 

1.

Preferred option: Have a Dometic authorized Servicing Dealer, perform the work needed. The customer needs to call 
Dometic Customer Service Department for a recommendation as to the closest dealer. If the customer already knows 
an authorized servicing dealer, the dealer should be contacted directly.

2.

Second option: If the customer contacts Dometic Service Department for a Servicing Dealer and Dometic has no one 
in that particular area, Dometic will authorize the use of a local service company and Dometic will work with the local 
company to assist in any way possible.

3.

Third option: The customer may send his equipment back to the factory to have the repair work done. Dometic will 
make every effort to return the equipment to the customer within a three week time period. If the claim represents a 
legitimate warranty problem, Dometic will pay the freight both ways. Dometic prefers option one first, option two 
second, and option three only if one and two are not available.

The customer may contact the Dometic Service Department at 954-973-2477 Monday through Friday, 8:00am - 5:00pm Eastern 
Time. After hours (evenings and weekends) technical support is offered through Dometic's 24/7 Hotline at 888-440-4494.  

Содержание DuraSea

Страница 1: ...Group Every precaution has been taken in the preparation of this manual to ensure its accuracy However Dometic Group assumes no responsibility for errors and omission Neither is any liability assumed...

Страница 2: ...UNIT ON THE ROOF 6 INSTALLING THE UNIT 6 WIRING SYSTEM TO POWER SUPPLY CONNECTION 9 AIR DISTRIBUTION BOX INSTALLATION 10 Operating Instructions 11 CONTROLS 11 OFF Position 11 Cooling Operation 12 Heat...

Страница 3: ...can support 130 pounds 59 kg of weight when the boat is in motion If applicable Roof construction with rafters joists on minimum of 16 inch 40 64 cm centers Minimum of 1 inch 2 54 cm and maximum of 4...

Страница 4: ...faces Specifications Table 1 Product Specifications Model 115 VAC 60 Hz Nominal Capacity BTU hr Cooling 15 000 Electrical Rating 120 VAC 60 Hz 1 Phase Running Amps 15 3 Compressor Locked Rotor Amps 66...

Страница 5: ...determining your cooling requirements the following should be considered Size of boat Window area increases heat gain Amount of insulation in walls and roof Geographical location where the boat will...

Страница 6: ...requirement Check inside the boat s cabin for obstructions to the air distribution box i e space for doors to open room dividers curtains ceiling fixtures etc See Figure 2 Figure 2 Interior Dimension...

Страница 7: ...359 mm it must be enlarged to 14 25 x 14 25 1 8 or 362 x 362 mm 3 mm NEW OPENING INSTALLATION OTHER THAN VENT OPENING 1 Mark a 14 25 x 14 25 1 8 or 362 x 362 mm 3 mm square on the roof and carefully...

Страница 8: ...rdered separately inside the boat This box contains mounting hardware for the unit and will be used inside the boat 3 Place the unit on the roof 4 Lift and place the unit over the prepared opening usi...

Страница 9: ...over blower discharge See Figure 6 Note Edges without flanges install toward REAR and SIDE of opening See Figure 6 Figure 6 Align Distribution Box s Upper Duct With Blower Discharge 5 Use two 2 10 x...

Страница 10: ...mplate up to the 14 25 x 14 25 1 8 or 362 x 362 mm 3 mm opening Start each mounting bolt through the ceiling template and up into the base pan by hand See Figure 9 Tighten all 4 bolts until they touch...

Страница 11: ...ground screw Tighten connector making sure not to damage wires 3 Connect white to white black to black using approved connectors Connect the bare copper wire to the ground screw located in the juncti...

Страница 12: ...ole plug into place at rear of air distribution box See Figure 14 4 There are four optional mounting holes on the outer edge of the return air opening for which screws are not provided These are only...

Страница 13: ...structions CONTROLS 1 The Selector Switch has 8 positions including OFF This controls fan speed heating mode optional and cooling modes See Figure 15 2 The Thermostat controls the temperature range at...

Страница 14: ...e air in your boat without cooling or heating There are three positions HIGH FAN MED FAN or LOW FAN to select from depending upon personal choice Maintenance AIR FILTER Periodically a minimum of every...

Страница 15: ...the manufacturer or its service agent or a similarly qualified person 4 When calling for service always give the following Unit type and serial number found on the identification label located on bas...

Страница 16: ...Frost Formation On Cooling Coil DuraSea Rooftop Installation Operations Manual 14 L 3075 ENGLISH Wiring Diagrams Figure 16 Unit Wiring Diagram Figure 17 Air Distribution Box Wiring Diagram...

Страница 17: ...liability or expense except as is specifically authorized and provided in this section Dometic reserves the right to improve its products through changes in design or material without being obligated...

Страница 18: ...and the date it is put in service In such instances the date of manufacture could indicate that the item is out of warranty However based on the date the equipment is first put in service the item ma...

Страница 19: ...ginal owner s warranty based on the original date of purchase or date of installation 2 Proof of purchase or installation may be required to verify warranty coverage 3 Any unit or replacement part ins...

Страница 20: ......

Отзывы: