background image

EN

Dometic Harrier Inverter

Accessories

7

5

Accessories

The following accessories are available for purchase separately.

If you have questions in respect of the accessories, please contact your local service 
partner.

6

Intended use

The Dometic Harrier inverter roof air conditioner can condition the interior of 
campers and caravans with cool or warm dehumidified air.

The roof air conditioner is 

not

 suitable for installation in construction machines, agri-

cultural machines or similar equipment. It will not work properly if exposed to strong 
vibrations.

Do 

not

 operate the roof air conditioner if the ambient temperature is above 52 °C.

I

No. in fig.

1

Number

Description

1

1

Roof air conditioner

2

1

Roof frame

3

1

Ceiling plate

4

1

ADB  cover

5

1

Duct insert

6

2

Air filter

7

1

Transition duct

8

3

Cable connector

9

4

Fastening bolt and washer

Description

Ref. no.

Thicker roof duct kit

81-535-DUCT3

NOTE 

You can find additional information on roof air conditioners in 
the operating manual, such as the technical description or the controls.

54-AA-MA53501.book  Seite 7  Dienstag, 19. Februar 2019  2:20 14

Содержание CK36H401RI Harrier Inverter

Страница 1: ...Harrier Inverter CK36H401RI CK36H401RIY Air conditioning roof unit Installation Manual EN CLIMATE CONTROL HARRIER 54 AA MA53501 book Seite 1 Dienstag 19 Februar 2019 2 20 14 ...

Страница 2: ...54 AA MA53501 book Seite 2 Dienstag 19 Februar 2019 2 20 14 ...

Страница 3: ...roup for this instruction manual 6 4 Scope of delivery 6 5 Accessories 7 6 Intended use 7 7 Unit identification 8 8 Installation 9 9 Troubleshooting 21 10 Disposal 23 11 Technical data 25 1 Explanation of symbols D DANGER Safety instruction Failure to observe this instruction will cause death or serious injury WARNING Safety instruction Failure to observe this instruction can cause death or seriou...

Страница 4: ...ar with the risks involved and the relevant regulations Inadequate repairs may cause serious hazards For repair service please contact the service centre in your country addresses on the back page Electrical devices are not toys Keep electrical devices out of reach of children or infirm persons Do not allow them to use electrical devices without supervision Persons whose physical sensory or mental...

Страница 5: ... the device as intended The roof air conditioner is not suitable for use in agricultural or con struction vehicles Do not make any alterations or conversions to the device Never drive through automatic car washes when the roof air condi tioner is mounted If faults occur in the refrigerant circuit the system must be checked by a specialist company and repaired properly The refrigerant must never be...

Страница 6: ...cts to lay cables through walls with sharp edges Do not lay loose or bent cables next to electrically conductive materials metal Do not pull on the cables 3 Target group for this instruction manual The instructions in this manual are intended for qualified personnel at workshops who are familiar with the guidelines and safety precautions to be applied 4 Scope of delivery 3 4 6 5 9 2 1 7 8 1 54 AA ...

Страница 7: ...nes agri cultural machines or similar equipment It will not work properly if exposed to strong vibrations Do not operate the roof air conditioner if the ambient temperature is above 52 C I No in fig 1 Number Description 1 1 Roof air conditioner 2 1 Roof frame 3 1 Ceiling plate 4 1 ADB cover 5 1 Duct insert 6 2 Air filter 7 1 Transition duct 8 3 Cable connector 9 4 Fastening bolt and washer Descrip...

Страница 8: ... side ventilation grille This label provides details on the rooftop unit Another label is located on the inside of the ADB cover giving details of the ADB 7 1 Rooftop unit Data label is located on the side of the electrical box under the top cover It is visible through the side vent if the unit 7 2 Air distribution box Another label is located on the inside of the ADB cover giving details of the A...

Страница 9: ...er installation of the roof air conditioner can result in irreparable damage to the device and put the safety of the user at risk The manufacturer assumes no liability for malfunctions and for the safety of the roof air conditioner especially for injury and or damage to property if the roof air conditioner is not fitted in accordance with these installation instructions Always wear the recommended...

Страница 10: ...pening for the installation of the roof air conditioner can be made without any risk of weakening the construction or cutting power cables If not fitment of a roof H frame may be required These are available separately Select a flat and sufficiently level area at the centre of the vehicle roof between two longitudinal sections for installation The roof inclination of the installation surface may n...

Страница 11: ...tallation side There are two ways of installing the roof air conditioner Making a new opening chapter Making a new opening on page 11 In this case the opening must be reinforced by an appropriate frame Using the existing roof hatch openings ventilation hatch in the vehicle chapter Installing in an existing opening on page 13 8 2 Making a new opening Select an area at the centre on the roof between...

Страница 12: ...electrical power cables are damaged Before installation check whether the roof hole needs reinforcing Frame the opening with appropriate sized wood or steel members to prevent collapsing when clamping the air conditioner If needed fit a suitable H frame to provide re enforcement to the roof A B 6 2 1 7 54 AA MA53501 book Seite 12 Dienstag 19 Februar 2019 2 20 14 ...

Страница 13: ...ing compound e g SikaLastomer 710 Selleys Butyl Mastic Bostik ezycaulk butyl sealant or similar NOTE Existing roof openings of 400 mm x 400 mm or 360 mm x 360 mm are suitable for installing the roof air conditioner Dispose of all waste material glue silicone and seals separately Observe the disposal guidelines The manufacturer only assumes liability for parts included in the scope of delivery The ...

Страница 14: ...A I DANGER Risk of electrocution Make sure there is no voltage at electrically operated components before carrying out work on them NOTE Allow enough length to connect the mains cables to the air conditioner without causing strain to the cables or connections NOTICE Risk of damage Observe the structural strength of the roof of the vehicle The roof of the vehicle must be able to bear the weight of ...

Страница 15: ... products Position the duct insert 1 into the roof frame 2 outside the RV Lift the roof air conditioner onto the roof of the vehicle NOTE Ensure the roof frame is oriented correctly based on opening size other wise this will cause problems with installation later refer to markings on the plate Marking indicating opening size in this case 400 mm flip over for a 360mm opening Arrow showing forward or...

Страница 16: ...op unit Gently pull them down into the RV Make the mains connections using either the wiring quick connectors provided or a suitable electrical junction box or terminals A Leave the communication cable free to be connected to the ADB transfer board later in the installation process DANGER Risk of electrocution Make sure there is no voltage at electrically operated components before carrying out wo...

Страница 17: ...de the RV I Roof thickness Seal type 30 60 mm transition duct included with ADB 60 105 mm thicker roof duct kit purchased separately NOTE Forthethickerroofductkitrefertotheinstructionsincludedwiththeseal kit NOTE Ensure the transition duct or seal is located correctly over the duct insert otherwise the performance of the unit may be affected 1 2 c d 54 AA MA53501 book Seite 17 Dienstag 19 Februar ...

Страница 18: ...he ADB ceiling plate will be held up while the clamping bolts are inserted Four bolts are used to clamp the rooftop unit and ceiling plate into place 3 are positioned in the corners while the 4th is slightly inbound Use the supplied washers with the bolts A NOTICE Risk of damage Tighten to the specified torque Ensure all 4 bolts are tightened by the same amount Uneven tight ening can cause distort...

Страница 19: ...B cover 1 the black 4 pin connector from the rooftop unit 2 8 9 Installing the ADB cover Place the ADB cover over the ceiling plate by clipping the front edge under the clips near the outlet vent then doing the same on the other side Be aware of the orientation of the cover as the display should align with the recessed area of the ceiling plate CN3 CN2 CN4 CN1 CN5 1 2 g h 54 AA MA53501 book Seite ...

Страница 20: ...ly pushing the bottom edge by hand this will not dam age the oscillation motors Clip the ADB cover on at the front and rear and ensure the magnets are engaged in the 4 corners Insert the 2 air filter elements Enter the new vehicle height and weight in the vehicle documents if required i 54 AA MA53501 book Seite 20 Dienstag 19 Februar 2019 2 20 14 ...

Страница 21: ...ure is below 16 C The roof air conditioner is only designed to cool at ambient temperatures above 16 C One of the temperature sensors is defective Contactanauthorised service agent or Dometic The evaporator fan is damaged The condenser fan is damaged Not heating well The roof air conditioner is not set to heating Set the roof air conditioner to heating The ambient temperature is below 2 C The roof...

Страница 22: ... is defective Contactanauthorised service agent or Dometic One of the temperature sensors is defective The electrical fuse of the power supply is too low Check the electrical fuse of the power supply Roof air condi tioner does not switch off One of the temperature sensors is defective Contactanauthorised service agent or Dometic The electrical fuse of the power supply is too low Check the electric...

Страница 23: ...ponents must be disposed of preferably recycled in compli ance with statutory legislation in the country in which disposal takes place For correct disposal the appliance must be consigned to an authorised waste disposal company to ensure that all recyclable components are reused and the remaining materials are processed properly During installation ensure the room has adequate ventilation to preve...

Страница 24: ...f refrigerant into the atmosphere is against the law Severe penalties apply M If you wish to finally dispose of the product ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations Dispose of the product at an official waste disposal facility in accordance with the applicable recycling or disposal guidelines B Prot...

Страница 25: ...nput voltage 220 240 Vw 50 Hz Power consumption in cooling mode 6 5 A Power consumption in heating mode 6 3 A Operating temperature range 2 C to 52 C Refrigerant R 410a Blower 3 blower levels 1 Automatic mode Suggested max vehicle length with insulated walls 7 5 m Dimensions L x W x H mm 1070 x 750 x 280 mm height above vehicle roof Weight 45 kg Inspection certification 4 10R 05 407 54 AA MA53501 ...

Страница 26: ...PE ye gn PE L N connect to ADB transfer PCB communication wire bk wh vt vt rd bk bk bk bu rd wh wh ye wh rd rd CN6 CN1 CN7 CN2 LX1 RT4 RT5 RT2 RT1 ϑ ϑ ϑ ϑ ϑ RT3 LX2 4V N1 AC L AC N PE CN3 COMU condenser fan evaporator fan reversing valve inverter compressor w v W V U u c c MAIN PCB 52 535 LSV02 ye gn Heatsink metal net Condenser Plate PE PE j 54 AA MA53501 book Seite 26 Dienstag 19 Februar 2019 2 ...

Страница 27: ...imensions Signal Wire 6 7 DISPLAY PCB CN1 CN2 CN4 bk rd bk rd CN6 CN1 CN1 LED PCB LED PCB Transfer PCB STEP Step Motor M STEP Step Motor M CN5 CN4 CN3 Air Purify CN2 CN1 Comu 52 535 LSV01 k 750 500 30 60 1070 280 66 520 620 400 640 360 l 54 AA MA53501 book Seite 27 Dienstag 19 Februar 2019 2 20 14 ...

Страница 28: ... dometic com dealer YOUR LOCAL SUPPORT dometic com contact dometic com A complete list of Dometic companies which comprise the Dometic Group can be found in the public filings of DOMETIC GROUP AB Hemvärnsgatan 15 SE 17154 Solna Sweden 4445101392 54 AA MA53501 01 2020 ...

Отзывы: