8.4
Running the electrical cables
D
The roof air conditioner must be connected to an electric circuit which is able to
supply the required current (see chapter “Technical data” on page 25).
➤
Select the cross-section of the cable corresponding to the length:
–
Length < 7.5 m: 1.5 mm²
–
Length > 7.5 m: 2.5 mm²
➤
Make an opening on one side in order to feed through the electrical power
supply cable.
➤
Feed the mains cable through the opening into the vehicle interior.
I
8.5
Installing the roof air conditioner ADB
A
I
DANGER! Risk of electrocution
Make sure there is no voltage at electrically operated components
before carrying out work on them!
NOTE
Allow enough length to connect the mains cables to the air conditioner
without causing strain to the cables or connections.
NOTICE! Risk of damage
Observe the structural strength of the roof of the vehicle. The roof of the
vehicle must be able to bear the weight of the roof air conditioner. The
roof must not be indented or deformed by the weight of the unit, even
over a longer period of time.
NOTE
Do not use sealant between the roof plate and the rooftop unit. It will
make later servicing difficult and is not required for weather sealing.
9