Note on electrical system
•
Only a qualified electrician should connect the roof air conditioner to the electri-
cal power.
•
Check that the voltage specification on the type plate is the same as that of the
power supply.
•
Do not lay cables which are loose or bent next to electrically conductive material
(metal).
•
Install an all-pole switch with a contact opening width of at least 3 mm on the
installation side.
There are two ways of installing the roof air conditioner:
•
Making a new opening (chapter “Making a new opening” on page 11). In this
case the opening must be reinforced by an appropriate frame.
•
Using the existing roof hatch openings (ventilation hatch) in the vehicle (chapter
“Installing in an existing opening” on page 13).
8.2
Making a new opening
➤
Select an area at the centre on the roof between two longitudinal supports.
➤
Mark the position and size of the opening using the template included in the
packaging (
A
and
B
) – either:
–
a x a = 400 x 400 mm
–
a x a = 360 x 360 mm
a
a
5