15
The exhaust gas duct system must be made in
such a manner as to achieve a complete
extraction of combustion products to the out-
side of living space. The flue gas is vented
directly through the upper grille. Do not use
any kind of aluminium flue pipe to lead the flue
gas out.
The T-piece (Fig. 23) must be aligned with the
exterior wall.
An installation other than described will
reduce the cooling capacity and jeopardi-
se the manufacturer's warranty/product
liability.
CAUTION!
Installation
4.5
Exhaust duct system
After the refrigerator is put in its final place,
secure the screws into the wall of the recess.
The screws must penetrate the casing of the
refrigerator.
Fig. 24
Fig. 25
In the sidewalls of the refrigerator, there are
four plastic sleeves for securing the refrigera-
tor. The sidewalls or strips attached for secu-
ring the refrigerator must be prepared to hold
the screws firmly in place even when under
increased load (while the vehicle is moving).
Fastening screws and caps are supplied with
the refrigerator.
4.6
Securing the refrigerator
Always insert screws through the sleeves
provided as otherwise components laid in
foam, such as cables etc., could be dama-
ged.
CAUTION!
Fig. 23
45°
289 0318-20_EN_RMD8xxx-Installation_N2.qxp 03.07.2012 13:07 Seite 15
Содержание ABSORPTION RMD 8501
Страница 2: ......
Страница 24: ...22 Installation 4 9 5 Circuit diagrams Fig 38 1 C D B A...
Страница 26: ......
Страница 28: ...2 Dometic GmbH 2012 nderungen vorbehalten Dometic GmbH In der Steinwiese 16 D 57074 Siegen www dometic com...
Страница 48: ...22 Einbau Abb 38 4 9 5 Schaltschema 1 C D B A...
Страница 50: ......
Страница 51: ......