Installation
The lip seals
(1)
are installed at the bottom and
on each side in the installation recess (Fig. 7-
9). A heat deflector plate
(2)
is installed in the
installation recess above the refrigerator.
Affix
this plate to the caravan wall, do NOT
attach to the refrigerator !
Insert deflector plate in such a way that the hot
air escapes through the air vent grille into the
open air.
The refrigerator is later pushed into the instal-
lation recess from the front. Ensure that the
seals abut the case evenly.
This installation option facilitates the removal
and installation of the appliance for servicing.
Abb. 8
Fig. 7
Fig. 9
1
1
2
2
Proposal 1
The cavity in-between the outer vehicle wall
and refrigerator is completely isolated from the
vehicle interior. Intrusion of exhaust fumes into
the living space is prevented. Fumes will esca-
pe through the upper ventilation grille to the
outside.
The draught-proof installation does not requi-
re a special exhaust gas duct to be used. .
Deviations require the consent of the
manufacturer!
Fig. 10
Fasten the sealing lips to a stop bar on the
rear side
(1)
, e.g. by gluing.
1
Proposal 2
289 0318-20_EN_RMD8xxx-Installation_N2.qxp 03.07.2012 13:07 Seite 11
Содержание ABSORPTION RMD 8501
Страница 2: ......
Страница 24: ...22 Installation 4 9 5 Circuit diagrams Fig 38 1 C D B A...
Страница 26: ......
Страница 28: ...2 Dometic GmbH 2012 nderungen vorbehalten Dometic GmbH In der Steinwiese 16 D 57074 Siegen www dometic com...
Страница 48: ...22 Einbau Abb 38 4 9 5 Schaltschema 1 C D B A...
Страница 50: ......
Страница 51: ......