background image

5

6. SERVICE

 - Unit Does Not Operate

If your unit fails to operate or operates improperly, check
the following before calling your service center.
A. If your RV is connected to motor generator, check to

be sure motor generator is running and producing
power.

B. If RV is connected to power supply by a land line,

check to be sure line is sized properly to run air
conditioner load and it is plugged into power supply.

C. Check your 115 VAC fuse or circuit breaker to see if it

is open.

D. Check your 12 VDC Fuse or Circuit Breaker to see if

it is open.

E. After the above checks, call your local service center

for further help. This unit must be serviced by qualified
service personnel only.

When calling for service, always give the following:

When calling for service, always give the following:

When calling for service, always give the following:

When calling for service, always give the following:

When calling for service, always give the following:

a. Air Conditioner Model Number and Serial Number
found on Rating Plate located on Base Pan of Air
Conditioner.
b. Electronic Control Kit Part Number and Serial Num-
ber found on Rating Plate located on side of Kit.

RETURN AIR GRILLE MUST BE REMOVED FROM

RETURN AIR GRILLE MUST BE REMOVED FROM

RETURN AIR GRILLE MUST BE REMOVED FROM

RETURN AIR GRILLE MUST BE REMOVED FROM

RETURN AIR GRILLE MUST BE REMOVED FROM
RETURN AIR COVER TO VIEW  THESE RATING PLATES

RETURN AIR COVER TO VIEW  THESE RATING PLATES

RETURN AIR COVER TO VIEW  THESE RATING PLATES

RETURN AIR COVER TO VIEW  THESE RATING PLATES

RETURN AIR COVER TO VIEW  THESE RATING PLATES

INST

INST

INST

INST

INSTALLA

ALLA

ALLA

ALLA

ALLATION INSTR

TION INSTR

TION INSTR

TION INSTR

TION INSTRUCTIONS

UCTIONS

UCTIONS

UCTIONS

UCTIONS

1.

1.

1.

1.

1. PRECAUTIONS

PRECAUTIONS

PRECAUTIONS

PRECAUTIONS

PRECAUTIONS

W

W

W

W

WARNING

ARNING

ARNING

ARNING

ARNING

IMPROPER  INSTALLATION MAY DAMAGE EQUIP-

IMPROPER  INSTALLATION MAY DAMAGE EQUIP-

IMPROPER  INSTALLATION MAY DAMAGE EQUIP-

IMPROPER  INSTALLATION MAY DAMAGE EQUIP-

IMPROPER  INSTALLATION MAY DAMAGE EQUIP-
MENT, COULD ENDANGER LIFE, CAUSE SERIOUS

MENT, COULD ENDANGER LIFE, CAUSE SERIOUS

MENT, COULD ENDANGER LIFE, CAUSE SERIOUS

MENT, COULD ENDANGER LIFE, CAUSE SERIOUS

MENT, COULD ENDANGER LIFE, CAUSE SERIOUS
INJURY AND/OR PROPERTY DAMAGE.

INJURY AND/OR PROPERTY DAMAGE.

INJURY AND/OR PROPERTY DAMAGE.

INJURY AND/OR PROPERTY DAMAGE.

INJURY AND/OR PROPERTY DAMAGE.

A. Read Installation and operating instructions carefully

before attempting to start your air conditioner installa-
tion.

B. The Dometic Corporation will not be liable for any

damages or injury incurred due to failure in following
these instructions.

C. Installation must comply with the National Electrical

Code and any State or Local Codes or regulations.

D. DO NOT add any devices or accessories to this air

conditioner except those specifically authorized by
Dometic.

E. This equipment must be serviced by qualified person-

nel and some states require these people to be

licensed.

2.

2.

2.

2.

2. CHOOSING LOCA

CHOOSING LOCA

CHOOSING LOCA

CHOOSING LOCA

CHOOSING LOCATION FOR 

TION FOR 

TION FOR 

TION FOR 

TION FOR THE

THE

THE

THE

THE

AIR CONDITIONER

AIR CONDITIONER

AIR CONDITIONER

AIR CONDITIONER

AIR CONDITIONER

This air conditioner is specifically designed for installation
on the roof of a recreational vehicle (RV).

A.

A.

A.

A.

A. For One Unit Installation

For One Unit Installation

For One Unit Installation

For One Unit Installation

For One Unit Installation:

The air conditioner should be mounted slightly forward of
center (front to back) and centered from side to side.

B.

B.

B.

B.

B. For Two Unit Installations

For Two Unit Installations

For Two Unit Installations

For Two Unit Installations

For Two Unit Installations:

Install  one air conditioner 1/3 and one air conditioner 2/3’s
from front of RV and centered from side to side.

It is preferred that the air conditioner be installed in a
relatively flat and level

flat and level

flat and level

flat and level

flat and level roof section measured with the RV

parked on a level surface. NOTE: UP TO AN 8° SLANT TO

NOTE: UP TO AN 8° SLANT TO

NOTE: UP TO AN 8° SLANT TO

NOTE: UP TO AN 8° SLANT TO

NOTE: UP TO AN 8° SLANT TO

EITHER SIDE, OR FRONT TO BACK, IS ACCEPTABLE.

EITHER SIDE, OR FRONT TO BACK, IS ACCEPTABLE.

EITHER SIDE, OR FRONT TO BACK, IS ACCEPTABLE.

EITHER SIDE, OR FRONT TO BACK, IS ACCEPTABLE.

EITHER SIDE, OR FRONT TO BACK, IS ACCEPTABLE.

5-3/8"

18"

7-3/4"

15"

7-3/4"

KEEP T HIS A REA F REE OF OBST RUCTIONS

AIR CONDIT IONER DIMENSIONS

(On T op of V ehicle)

REAR 
OF
UNIT

14" x 14"
OPENING

600 SERIES

600 SERIES

600 SERIES

600 SERIES

600 SERIES

14" x 14"
OPENING 

21-1/2"

KEEP T HESE A REAS
FREE OF OBST RUCTIONS

12"

REAR
OF
UNIT

4"

4"

4-1/4"

7-1/4"

7-1/4"

Center L ine
of Unit

579, 590 & 595 SERIES

579, 590 & 595 SERIES

579, 590 & 595 SERIES

579, 590 & 595 SERIES

579, 590 & 595 SERIES

C.

C.

C.

C.

C. AFTER LOCATION HAS BEEN SELECTED:

AFTER LOCATION HAS BEEN SELECTED:

AFTER LOCATION HAS BEEN SELECTED:

AFTER LOCATION HAS BEEN SELECTED:

AFTER LOCATION HAS BEEN SELECTED:

1.

Check for obstructions in the area where air
conditioner will be installed.

2.

The roof must be designed to support 130 pounds
when the RV is in motion. Normally 200 pound
static load design will meet this requirement.

AIR CONDITION DIMENSIONS

AIR CONDITION DIMENSIONS

AIR CONDITION DIMENSIONS

AIR CONDITION DIMENSIONS

AIR CONDITION DIMENSIONS

(On Top of Vehicle)

(On Top of Vehicle)

(On Top of Vehicle)

(On Top of Vehicle)

(On Top of Vehicle)

Содержание 57908.521

Страница 1: ...aide ou des obtenir de l aide ou des obtenir de l aide ou des reseignements compl mentaires reseignements compl mentaires reseignements compl mentaires reseignements compl mentaires reseignements com...

Страница 2: ...the ceiling windows metal parts etc The air conditioner removes this moisture from the air during normal operation Keeping doors and windows closed when this air conditioner is in opera tion will mini...

Страница 3: ...e ZONE 1 ZONE 1 ZONE 1 ZONE 1 ZONE 1 2 2 2 2 2 3 3 3 3 3 or 4 4 4 4 4 2 The mode of operation is selected by momentarily depressing the MODE MODE MODE MODE MODE pushbutton 3 The fan speed is selected...

Страница 4: ...ter in place This may plug the unit evaporator coil filter in place This may plug the unit evaporator coil filter in place This may plug the unit evaporator coil filter in place This may plug the unit...

Страница 5: ...ing these instructions C Installation must comply with the National Electrical Code and any State or Local Codes or regulations D DO NOT add any devices or accessories to this air conditioner except t...

Страница 6: ...the Air Conditioner NOTE NOTE NOTE NOTE NOTE THE DOMETIC CORPORATION WILL NOT BE HELD THE DOMETIC CORPORATION WILL NOT BE HELD THE DOMETIC CORPORATION WILL NOT BE HELD THE DOMETIC CORPORATION WILL NO...

Страница 7: ...LIES AND THE POSITIVE TERMI POWER SUPPLIES AND THE POSITIVE TERMI NAL FROM THE SUPPLY BATTERY FAILURE TO NAL FROM THE SUPPLY BATTERY FAILURE TO NAL FROM THE SUPPLY BATTERY FAILURE TO NAL FROM THE SUPP...

Страница 8: ...ve the floor b Install the Comfort Control Center on a partition not on an outside wall FRAME 14 OP ENING AC P OWER SUPPLY W IRE DUCT FRAME FRAME THERMOSTAT CA BLE DUCT ROOF INSULATION DUCT T O REA R...

Страница 9: ...air opening of the Air Conditioner and pull the unit electrical cord down for later connection C C C C C COMFORT CONTROL CENTER INSTAL COMFORT CONTROL CENTER INSTAL COMFORT CONTROL CENTER INSTAL COMFO...

Страница 10: ...LATE INSTALLATION OF DIVIDER PLATE INSTALLATION OF DIVIDER PLATE INSTALLATION OF DIVIDER PLATE 1 Measure the ceiling to roof thickness a If distance is 2 00 3 75 remove perforated tab from Divider Pla...

Страница 11: ...s approved for use on 590 Series Air Conditioners only Follow the instructions with the heat package for only Follow the instructions with the heat package for only Follow the instructions with the he...

Страница 12: ...ntrol Bo Electronic Control Box The polarity of these connections does not matter 4 Connect the previously run Energy Management System wires if applicable to the yellow wires protruding from the Elec...

Страница 13: ...configuration I I I I I INSTALLATION OF RETURN AIR COVER INSTALLATION OF RETURN AIR COVER INSTALLATION OF RETURN AIR COVER INSTALLATION OF RETURN AIR COVER INSTALLATION OF RETURN AIR COVER 1 Remove R...

Страница 14: ...ING DIAGRAM UNIT FIELD WIRING DIAGRAM UNIT FIELD WIRING DIAGRAM UNIT FIELD WIRING DIAGRAM UNIT FIELD WIRING DIAGRAM UNIT FIELD WIRING DIAGRAM RED BLU 3105052 009 RED BLK YEL RED GRN YEL GRN YEL WHT WH...

Отзывы: