![Dometic 57908.321 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/dometic/57908-321/57908-321_installation-instructions-manual_2518155011.webp)
11
INSTALLATION INSTRUCTIONS DUCTED CCC
A. 579, 590, 591 AND 595 SERIES
1.
Insert the Freeze Control Sensor approximately 1" into the fins of the evaporator coil as shown in FIG. 9. Bend fins
over sensor to secure in place.
2. Plug the freeze control sensor cord into the mating connector on the Electronic Control Kit. These connectors are
polarized and will easily snap together. DO NOT FORCE.
8. INSTALLATION OF COLD CONTROL
B. 600 & 630 SERIES
1.
Insert the Freeze Control Sensor approximately 1" into the evaporator coil fins located at the right side of the evaporator,
as shown in FIG. 10. Bend fins over sensor to secure in place.
2. Plug the freeze control sensor cord into the mating connector on the Electronic Control Kit. These connectors are
polarized and will easily snap together. DO NOT FORCE.
8. WIRING OF CONTROL SYSTEM
A. CONNECTION OF 115 VOLT AC SUPPLY
1.
Reach up into the return air opening of the air conditioner and pull the unit electrical cord down for later installation. See
FIG. 11.
AC Power
Supply
Pull Electrical
Cord Down
Roof
Gasket
FIG. 11
Disconnect 115 volt AC. Failure to follow
these instructions could create a shock haz-
ard causing death or severe personal injury.
This product is equipped with a 3-wire
(grounded) system for protection against
shock hazard. Make sure that the appliance
is wired into a properly grounded 115 volt AC
circuit and the polarity is correct. Failure to
do so could result in death, personal injury
or damage to the equipment.
DC Power
Supply
WARNING
!
WARNING
!
FIG. 10
600 & 630 FREEZE CONTROL
Freeze Control with wires.
D
o
kd
kd
m
fm
f
Remove
Hang
Tag
Insert Freeze Control
Sensor at a slight angle
between bottom coil
approximately 1
”
Bend fins over
sensor to hold
in place
Freeze control
sensor
FIG. 9
579, 590 & 595 FREEZE CONTROL
Freeze Control with
wires to the right side
Remove
Hang
Tag
Insert Freeze
Control Sensor
at a slight angle
between bottom
coil approximately 1
”
Freeze control
sensor
Bend fins over
sensor to hold
in place