Dometic 57908.321 Скачать руководство пользователя страница 10

10

INSTALLATION INSTRUCTIONS DUCTED  CCC

PLEASE R ECYCLE
ALL C ARDBOARD

FIG. 7

Please Recycle All
Cardboard

7. PLACING THE AIR CONDITIONER ON THE ROOF

A. Remove the air conditioner from the carton and discard carton. The unit mounting bolts and literature are in separate plastic

bag. Be sure to place this information in the RV.

B. Place the air conditioner on the roof.

FIG. 8

REAR REMOTE SENSOR
(Required with Second
Air Conditioner)

REAR REMOTE SENSOR
(Required with Second
Air Conditioner)

14-1/4" x 14-1/4"
(±1/8”) OPENING

14-1/4" x 14-1/4"
(±1/8”) OPENING

14-1/4" x 14-1/4"
(±1/8”) OPENING

14-1/4" x 14-1/4"
(±1/8”) OPENING

OPTIONAL
FURNACE

OPTIONAL
FURNACE

FURNACE
2 WIRES

FURNACE
2 WIRES

OPTIONAL FRONT
REMOTE SENSOR

OPTIONAL FRONT
REMOTE SENSOR

12V DC INPUT
2 WIRES

12V DC INPUT
2 WIRES

FURNACE

4-CONDUCTOR
CONTROL CABLE

4-CONDUCTOR
CONTROL CABLE

BREAKER BOX

BREAKER BOX

115V AC
REAR A/C

115V AC
REAR A/C

4-CONDUCTOR
CONTROL CABLE

4-CONDUCTOR
CONTROL CABLE

115V AC
FRONT A/C

115V AC
FRONT A/C

FURNACE
2 WIRES

FURNACE
2 WIRES

DOMETIC COMFORT
CONTROL CENTER

DOMETIC COMFORT
CONTROL CENTER

FIG. 6

C. Lift and place the unit over the prepared opening usingthe gasket on unit as a guide. The roof gasket on the bottom of the

base pan goes toward the front of the RV. Sliding the unit on the roof will damage the roof gasket. See FIG. 8.

Do not slide the unit. This may damage the
neoprene gasket attached to the bottom and
create a leaky installations.

CAUTION

D. AIR DISTRIBUTION DUCT INSTALLATION

1. Install the Air Distribution Ducts in the RV Roof Cavity. The Distribution System must meet:

a. RV’s requirements
b. System requirements listed in Section 4 on page 6 of this Manual. Terminate the start of the Duct at the back edge

of the 14-1/4" x 14-1/4" (±1/8")  opening previously cut. See FIG. 2, 3 &  4.

This unit weighs approximately 100 pounds.
To prevent back injury, use a mechanical
hoist to place air Conditioner on roof.

CAUTION

!

Содержание 57908.321

Страница 1: ...ic Control Kit Ducted 59136 531 59136 536 59136 621 59136 631 59516 303 59516 331 59516 336 59516 501 59516 531 59516 536 59516 601 59530 632 600312 321 600315 326 600312 421 600315 321 600315 421 630...

Страница 2: ...erature For a more permanent solution to high heat gain accesso ries like A E outdoor patio and window awnings will reduce heat gain by removing the direct sun They also add a nice area to enjoy compa...

Страница 3: ...1 3 62 0 2 5 5 8 325 250 0 55 0 90 16 0 20 Amp 94 3 5 KW 5 0 KW 57915 621 13 500 11 0 54 4 2 5 5 8 325 250 0 55 0 90 16 0 20 Amp 94 3 5 KW 5 0 KW 57915 622 13 500 11 0 54 4 2 5 5 8 325 250 0 55 0 90 1...

Страница 4: ...31 N A 8 0 48 3 2 0 5 6 325 250 0 40 1 10 19 0 15 Amp 94 3 5 KW 5 0 KW 59530 531 N A 7 8 53 0 2 0 5 6 325 250 0 40 1 10 19 0 15 Amp 94 3 5 KW 5 0 KW 59530 532 N A 8 0 53 0 2 5 5 8 325 250 0 40 1 10 18...

Страница 5: ...front to back and centered from side to side B For Two Unit Installations Install one air conditioner heat pump one third and one airconditioner heatpumptwo thirdsfromfrontofRVand centered from side t...

Страница 6: ...ductwork will not collapse or bend during and after the installation Dometic Corporation will not be liable for roof struc tural or ceiling damage due to improperly in sulated sealed or collapsed duc...

Страница 7: ...be electrical wiring between the roof and the ceiling Disconnect 115 volt AC power cord and the positive 12 volt DC terminal at the supply battery Failure to fol low this instruction may create a sho...

Страница 8: ...Duct Size And Requirements For 3105007 XXX And 3105935 XXX Return Air Cover Duct Size And Requirements For 3308120 XXX Genesis Air Filtration System Total Outlet Air Area Minimum 21 0 Sq In Total Outl...

Страница 9: ...dedicated 12VDC supply line 18 to 22 AWG from the RV s converter or battery to the roof opening a This supply line must be located in the front portion of the 14 1 4 x 14 1 4 1 8 opening b Make sure t...

Страница 10: ...V AC REAR A C 115V AC REAR A C 4 CONDUCTOR CONTROL CABLE 4 CONDUCTOR CONTROL CABLE 115V AC FRONT A C 115V AC FRONT A C FURNACE 2 WIRES FURNACE 2 WIRES DOMETIC COMFORT CONTROL CENTER DOMETIC COMFORT CO...

Страница 11: ...f the air conditioner and pull the unit electrical cord down for later installation See FIG 11 AC Power Supply Pull Electrical Cord Down Roof Gasket FIG 11 Disconnect 115 volt AC Failure to follow the...

Страница 12: ...nterTM CCC cable previously terminated see Section 6 B Control Cable into one of the control cable leads out of the air conditioner Either one of the two 2 control cables can be used 6 Connect the rem...

Страница 13: ...sive The foam divider should be level with the ceiling 1 4 Tear off the excess at the pre cut perforations in divider See FIG 13B 2 Peel the paper off of the foam divider and stick it in place on the...

Страница 14: ...ed See FIG 16B for Brisk Air unit and Fig 17B for Penguin units FIG 15A Installing unit with 3308120 XXX Genesis Air Filtration System continued on page 15 column B FIG 16A If bolts are left loose the...

Страница 15: ...luminum foil tape not supplied to seal the ends of the foam divider to the sides of the opening Make sure the area behind the flange on the ceiling template is sealed See FIG 18B FIG 18B Use Aluminum...

Страница 16: ...t power be supplied to the air conditioner and check for proper operation Refer to Operating Manual or User s Guide for a description of the air conditioner operation Installing unit with 3308120 XXX...

Страница 17: ...e shortened by placing the Differential dip switch in the ON position Note Setting the Differential dip switch should only be required when the installation conditions are less than desirable and is n...

Страница 18: ...579 590 591 595 600 630 579 590 591 595 600 630 509 S POPLAR ST 509 S POPLAR ST LAGRANGE IN 46761 LAGRANGE IN 46761 115VAC 60Hz 1 O 115VAC 60Hz 1 O 60 HZ 1 O 60 HZ 1 O 3106515 020 USE COPPER USE COPPE...