3311145.000 Secondary Burner Housing Kit Service Instructions
4
Overview of rear equipment before starting the
service kit installation.
Step 1. Remove refrigerator lower side vent ac-
cess door.
Important: Before starting the installation:
A. determine if Item (1) back protection plate
(See illustration in step 8)
and/or
B. determine if Item (2) bottom plate (See il-
lustration in step 7)
will slide into place without disconnecting
the gas line or removing the burner.
If for any reason the gas line or burner
requires loosening or removal a gas leak
test is required. (See step 21 & 37)
If gas line or burner does not require loos-
ening or removal proceed to step 7.
If loosening or removal are required con-
tinue with step 2.
The bottom plate has two score lines on
it. You may need to shear the bottom
plate off at these locations to get it to fi t
on units that already have a sheet metal
barrier under the burner.
Note:
Make sure the tabs identifi ed with arrows
in the photo below are facing up.
Explosion hazard. LP gas ignition could occur.
Shut off the LP gas supply at the tank before
disconnecting the LP gas line. Failure to heed
this warning may cause severe personal injury
or property damage.
Step 2. Turn “OFF” LP gas supply at tank.
Disconnect the LP gas line at the re-
frigerator. Use back up wrenches to
secure the gas valve during removal
of gas line. Plug gas line with appro-
priate size and type plug to prevent
accidental LP gas discharge if LP gas
tank is prematurely turned on.
Step 1
Step 1
Step 1
Step 1