3311145.000 Secondary Burner Housing Kit Service Instructions
10
Step 22. Secure the bottom plate with two sup-
plied #8 x 1-3/8" screws, Item (16). Be
careful not to over tighten. The bot-
tom plate should not defl ect or bend.
If a pre-existing sheet metal barrier
is present, you will need to drill holes
in it that correspond with the holes in
the bottom plate. The provided drill bit
can be used for this function.
Step 22
Step 22
Step 22
Step 22
Step 22
Step 22
Step 20. Using two open end wrenches, make
sure the LP gas connection is tight.
Step 20
Step 20
Step 21. Turn “ON” the LP gas tank. Make
sure the refrigerator gas valve is also
turned to the “ON” position. Using a
calibrated manometer and a certifi ed
gas technician, conduct a pressure
"DROP" leak test on the LP gas sys-
tem per approved industry standard.
Personal injury hazard. If the RV continues to in-
dicate a gas leak by the decay of a manometer,
the leak must be repaired before the gas system
is allowed to be left on. Do not operate the RV
with an LP leak at any location on the system.
Step 24. Skip this step for integrated ignition
modules. Remove the screw holding
the power module cover in place (a).
Use a fl at-head screwdriver to pry open
the plastic cover (b) and remove.
(a)
Step 24
Step 24
Property damage hazard. Cap 12 VDC (+) pos-
itive wire with a wire nut. Failure to heed this
warning could cause property damage
Step 23. Disconnect the incoming red (+) posi-
tive wire from the 12 VDC terminal
block. Cap wire with appropriate size
wire nut to prevent accidental contact
with other objects if 12 VDC is prema-
turely reconnected.