BC
2003BM User Manual
www.dolphinsolutions.co.uk
1. Make sure power supply breaker is switched off. Installation must be carried out in
accordance with the current edition of the local wiring regulations code having jurisdiction.
Installation should be performed only by a qualified electrician.
2. Place template against wall at desired height (see mounting height recommendations)
and mark locations of 4 mounting holes and wire service entry at knockout (KO) location.
Note:
For two or more dryers, dryers should be no closer than 24 inches (610mm)
on center.
Remove and retain 2 cover screws and cover.
K.O hole
Back
Back
K.O hole
Operating Instructions and Parts Manual
Hand drier
Connect the wire into terminal as below:
Connections:
A. Connect the live wire (colored red or black or brown)
to the terminal block marked "L".
B. Connect the neutral wire (colored white or blue)
to the terminal block marked "N".
C. Connect the ground wire (colored green or green and yellow)
to the terminal block marked " ".
Installation
1
4
Fix the part to the wall with 4 screws of
1/4 x 1-3/4 dimension.
"
2
Insert the power cord into the suitable K.O. hole.
5
Put the front cover back and screw it with L key.
3