background image

BC

2003BM  User Manual 

www.dolphinsolutions.co.uk

LIMITED  THREE-YEAR  WARRANTY

Warranty

Please  see  our  website  by  following  this  link:  http://www.dolphinsolutions.co.uk/
or  contact  our  customer  service  team  on  01424  202224  for  more  details.

Operating  Instructions  and  Parts  Manual 

Hand  drier

Diagnostics  and  Remedies

If  the  dryer  will  not  run

The  dryer  cycles  by  itself

or  runs  constantly

The  dryer  runs  but  air

stream  is  low  pressure

and/or  low  velocity

Ensure  that  there  is  no  obstruction  on  or  in  front  of  the  IR  sensor.  Clean

any  dirt  or  debris  off  the  sensor  lens.  If  problem  persists,  replace  sensor.

First  ensure  that  the  breaker  supplying  the  dryer  is  operational.  If  it  is,

disconnect  the  power  and  remove  the  dryer  cover.  Taking  suitable

precautions  to  avoid  shock  hazard,  reconnect  the  power  and  check  for

Voltage  at  the  terminal  block.  Verify  that  connections  are  made  correctly.

Ensure  that  the  supply  Voltage  is  correct.    Dryer  will  run  weakly  if  the

input  Voltage  is  too  low.    Verify  Voltage  requirement  on  unit  rating  label

and  correct  supply  as  required.

The  dryer  makes  a  loud

noise  and  does  not  run

for  a  complete  cycle

Ensure  that  the  supply  Voltage  is  correct.  Dryer  will  make  a  loud  humming

noise  if  the  input  Voltage  is  too  high.  Verify  Voltage  requirement  on  unit

rating  label  and  correct  supply  as  required.  If  CBM  has  been  damaged,

replace  CBM,  IR  sensor  module  and  VR  component  and  cable.

Symptom                                                                                                                                 

Corrective  Actions  for  Initial  Installation  Failures

Symptom                                                                                                                                 

Corrective  Actions  for  In-Service  Failures

If  the  dryer  will  not  run

The  IR  sensor  only  sees

close  range  objects

"

"

The  dryer  only  blows  cold

air  during  a  full  cycle

First  ensure  that  the  breaker  supplying  the  dryer  is  operational.  If  it  is,

disconnect  the  power  and  remove  the  dryer  cover.  Replace  the  CBM

and  IR  sensor  module.  Taking  suitable  precautions  to  avoid  shock 

hazard,  reconnect  the  power  and  check  for  voltage  at  the  terminal  block.

Disconnect  the  power.  Remove  the  dryer  cover  and  disassemble  the 

blower-motor/fan  housing.  Test  the  thermostat  for  open  circuit.  Check 

the  heater  element  for  signs  of  burning  or  breakage.  Damaged  element 

must

 

be  replaced.

The  heater  gets  hot  but

no  air  stream  is  produced

or  the  air  stream  is  low

pressure  and  velocity 

Disconnect  the  power.  Remove  the  dryer  cover  and  disassemble  the

 

blower-

motor/fan  housing.  Replace  the  fan  motor.

Ensure  that  there  is  no  obstruction  on  or  in  front  of  the  IR  sensor.  Clean

any  dirt  or  debris  off  the  sensor  lens.  Check  VR  for  sensor  range  setting,  If   

problem  persists,  disconnect  the  power  and  remove  the  dryer  cover  and 

replace  CBM,  IR  sensor  module.

Содержание VELOCITY BC 2003BM

Страница 1: ...BC2002 DOLPHIN HAND DRYER BC2003BM DOLPHIN BEHIND MIRROR HIGH SPEED HAND DRYER U S E R M A N U A L...

Страница 2: ...Vac 50 60Hz 0 84 1 0kW 90m s adjustable 250 500W 29000r p m Adjustable Brush Type Dual Ball Bearings Auto Resetting Thermostat turns unit off at 95 C 203 F 500W adjustable Auto Resetting Thermostat tu...

Страница 3: ...stor Power Switch VR G N L Red 110 120V Brown 208 240 277V Black Black G Y Blue Brown Motor With Thermal Switch 2A Heater With Thermo fuse FOR SENSOR SW FOR HEATER White 110 120V Blue 208 240 277V Sen...

Страница 4: ...e dryers dryers should be no closer than 24 inches 610mm on center Remove and retain 2 cover screws and cover K O hole Back Back K O hole Operating Instructions and Parts Manual Hand drier Connect the...

Страница 5: ...dust lint from the interior of the dryer Replace the cover Do not over tighten the screws Wipe the cover with a damp cloth and mild cleaning solution Do not Soak Never use abrasives to clean the cove...

Страница 6: ...nge 4 DO NOT OVERTURN SW FOR HEATER Use phillips screw to adjust air speed Install the cover once adjustment is completed Clockwise Increases the air speed Counterclockwise Decreases the air speed A W...

Страница 7: ...lacement 1 Pull off the four wires and remove the fixing screws of the timer 2 Ensure that the two flanges on the timer to be wedged in the two holes are on the base plate 3 Fix the timer to the blowe...

Страница 8: ...and Parts Manual Hand drier Surface mounted high speed hand drier Sensor replacement 1 Pull off the wires that connect timer and remove the fixing screws of the timer 2 Fix the sensor on the sensor b...

Страница 9: ...l www dolphinsolutions co uk Operating Instructions and Parts Manual Hand drier Motor replacement 1 Remove the wires that connect motor to the timer 2 Loosen the fixing screws of the blower and remove...

Страница 10: ...uk Operating Instructions and Parts Manual Hand drier 3 To replace the motor install the motor rubber large small on the motor and place the motor under the fan blower The wire set must be fixed to t...

Страница 11: ...www dolphinsolutions co uk Operating Instructions and Parts Manual Hand drier Heater replacement 1 Remove the wires that connect heater to the timer 2 Loosen the fixing screws of the blower and remov...

Страница 12: ...BC2003BM User Manual www dolphinsolutions co uk Operating Instructions and Parts Manual Hand drier 3 To replace the heater the wire set must be fixed to the ditch in the lower housing of the blower...

Страница 13: ...crewdriver Wire Cutter Modular Crimping Cuts Tool Important Information This Product falls within the scope of the Waste Electrical Electronic Equipment Directive 2002 96 EC WEEE NOTE This Product sho...

Страница 14: ...umming noise if the input Voltage is too high Verify Voltage requirement on unit rating label and correct supply as required If CBM has been damaged replace CBM IR sensor module and VR component and c...

Страница 15: ...r housing Upper Blower housing Below Motor Motor rubber Motor rubber Heater assembly Circuit Board Module Base plate Nylon hole bushing Small Large Description Insulation Mylar Terminal block Blower m...

Страница 16: ...nual www dolphinsolutions co uk Dolphin Solutions Ltd Southpoint Compass Park Junction Road Bodiam TN32 5BS United Kingdom T 44 0 1424 202 224 info dolphinsolutions co uk dolphinsolutions co uk Dolphi...

Отзывы: