8. PERIODIC OPERATION AND
INSPECTION
When furnishing the generator as emergency
electric power source, periodic operation and
inspection are needed.
Fuel (gasoline) and engine oil will be deteriorated
with time, and this causes that the engine is
difficult to start and as the results improper
engine operation and fault.
Since the fuel (gasoline) will be deteriorated
with time, replace fuel (gasoline) with fresh
one periodically; once every three (3)
months is recommended.
CAUTION
(a) Check the fuel (gasoline), engine oil and air
cleaner.
(b) Start engine.
(c) With appliance such as lightings activated,
run the engine for over ten minutes.
(d) Check for the following items;
■
■
Proper engine running.
■
■
Adequate output and the indicator lamp
turned on properly.
■
■
The engine switch normally operated.
■
■
No leakage of engine oil and fuel (gasoline).
9. TRANSPORTING
When transporting the generator, make sure that
the fuel (gasoline) should be drained from the
tank.
(a) Turn the engine switch to the
"
" (CLOSE) position.
(b) Drain the fuel from the tank.
■
■
To prevent fuel spillage due to the
vibration and impact, never transport
the generator with the fuel (gasoline)
filled in the tank.
■
■
Secure the tank cap thoroughly.
■
■
To avoid the risk of the gasoline
flammability, never leave the generator
in an area exposed to direct sunlight or
high temperatures for a long time.
■
■
Keep the fuel (gasoline) in the exclusive
gasoline storage tank made by steel
when transporting.
WARNING
(c) Secure the tank cap.
■
■
Do not place any heavy objects on the
generator.
■
■
Select and place the generator in the
proper position of the transport vehicle
so that the generator not be moved or
fallen down.
Fix the generator with rope as necessary.
CAUTION