3. STOPPING THE GENERATOR
(a) Turn off the power switch of the electric equipment
and unplug the cord from receptacle of the generator.
(b) Allow the engine about 3 minutes to cool down
at no load before stopping.
(c) Turn the engine switch to the position
"
" (CLOSE). (See Fig.
4
-
w
)
q
"
" (OPEN)
w
"
" (CLOSE)
4. OIL SENSOR (See Fig.
4
4
-
e
e
)
q
OIL SENSOR
(a) The oil sensor detects the fall in oil level in the
crankcase and automatically stops the engine
when the oil level falls below a predetermined
level.
(b) When engine has stopped automatically, switch
off generator's no fuse breaker, and check the
oil level.
Refill engine oil to the upper level as instructed
on page 5 and restart the engine.
(c) If the engine does not start by usual starting
procedures, check the oil level.
Do not remove OIL SENSOR PROBE when
refilling with oil.
Remove oil filler cap on the opposite side
of carburetor.
CAUTION
NOTE
When the AC circuit breaker turns off during
operation, the generator is over loaded or the
appliance is defective.
Stop the generator immediately, check the
appliance and / or generator for overloading, and
have repaired as necessary by DOLMAR factory
or authorized service center.
■
■
Be sure to ground the generator if the
connected electrical device is grounded.
■
■
Failure to ground unit could lead to
electrical shock.
WARNING
■
■
Check the amperage of the receptacles,
and be sure not to take a current exceeding
the specified amperage.
■
■
Be sure that the total wattage of all appliances
dose not exceed the rated output of the generator.
■
■
Be sure to ground the generator if the
connected electrical device is grounded.
WARNING
Do not put foreign objects into the plug
receptacle.
CAUTION