DOLD NE 5020 Скачать руководство пользователя страница 11

11

NE 5020 / 23.07.18 en / 004A

Function Diagram

Approvals and Markings

Additional Information about this topic

Applications

Function

Connections

Indicators

Notes

Block Diagrams

Safety Technique

Accessories for Safety Applications

Magnetic Switch coded
NE 5020

 

Usable for safety application by using a correctly installed and 

  connected, security module (e. g. BG 5925/920 or LG 5925/920) 

 

According to IEC/EN 60 204-1, EN 1088

  2 channel system

  Standard switching distance:  S

an

 

 5.5 mm

 

 

   S

ab

 

 13 mm

  2 NO semiconductor outputs providing diversity and redundancy

  Magnetic coded, safe against manipulation

  Open end connection wires

  M8 or M12 connector as option

  Long service life

  Easy to mount

  Resistant against vibration

  Not sensitive to external magnetic fields

  Protection class IP 67

  LED indicator

0233459

Sensing

distance S [mm]

3

7

Sab

San

Outputs 14; 24

LED

On

Off

* only when transmitter is used with the corresponding code

*

t

t

t

M7741

Decoder

Supply

(+)

(-)

(-)

(+)

S

Receiver channel 1

Receiver channel 2

Transmitter

Receiver

M7742

(white) A1

Mounting difference y

(yellow) 24

(brown) 14

(green) A2

Code

The magnetic switch NE 5020 includes a magnetic coded transmitter and 
a receiver as decoder. The semiconductor outputs close, when the recei-
ver recognises the right code from the transmitter. The control unit detects 
cross faults on the lines 14 and 24. The control unit is switched off when 
a fault is detected and inhibits a new start. The switch is protected against 
short circuits and peak voltages.

The NE 5020 is connected to the control unit BG 5925/920 or LG 5925/920 
according to the application example below.

The magnetic switch NE 5020 is suitable to detect the closed state of sa-
fety gates, sliding gates and removable covers also under rough ambient 
conditions or for hygienic requirements. The corresponding control unit is  
BG 5925/920 or LG 5925/920.

Drawing shows contacts in inactive state

green LED: 

 

switch is active, outputs switched on

The code of transmitter and receiver are identically on delivery. This can 
be verified by a mark on the test sticker.

  Data sheet control unit BG 5925/920 or LG 5925/920 for safety switch

All technical data in this list relate to the state at the moment of edition. We reserve the right for 
technical improvements and changes at any time.

Содержание NE 5020

Страница 1: ...rheitsanwendungen Magnetschalter kodiert NE 5020 0265983 Datenblatt Betriebsanleitung DEUTSCH E DOLD S HNE KG Postfach 1251 78114 Furtwangen Deutschland Telefon 49 7723 6540 Fax 49 7723 654356 dold re...

Страница 2: ...e 3 Funktionsdiagramm 5 Blockschaltbilder 5 Zulassungen und Kennzeichen 5 Weitere Informationen zu diesem Thema 5 Anwendungen 5 Aufbau und Wirkungsweise 5 Ger teanschluss 5 Ger teanzeigen 5 Hinweis 5...

Страница 3: ...entsprechenden Vorsichtsma nahmen nicht getroffen werden ACHTUNG Warnt vor Handlungen die einen Schaden oder eine Fehlfunktion des Ger tes der Ger teumgebung oder der Hard Software zur Folge haben k...

Страница 4: ...4 NE 5020 23 07 18 de 004A...

Страница 5: ...aus einem Aktor als magnetischer Codegeber und einem Sensor als Decoder Die 2 Halbleiterausg nge schlie en wenn der Sensor die richtige 2 kanalige Kodierung des Aktors erkennt Im Auswerteger t werden...

Страница 6: ...last mit V0 Verhalten nach UL Subj 94 R ttelfestigkeit Amplitude 0 35 mm Frequenz 10 55 Hz IEC EN 60 068 2 6 Klimafestigkeit 25 060 04 IEC EN 60 068 1 Kabelanschl sse 4 drahtig mit Aderendh lsen wei 2...

Страница 7: ...ications Magnetic Switch coded NE 5020 Datasheet Operating Instructions ENGLISH E DOLD S HNE KG P O Box 1251 D 78114 Furtwangen Germany Tel 49 7723 6540 Fax 49 7723 654356 dold relays dold com www dol...

Страница 8: ...ction Diagram 11 Block Diagrams 11 Approvals and Markings 11 Additional Information about this topic 11 Applications 11 Function 11 Connections 11 Indicators 11 Notes 11 Technical Data 12 Connection 1...

Страница 9: ...dicates that a minor personal injury can result if proper precautions are not taken ATTENTION Warns against actions that can cause damage or malfunction of the device the device environment or the har...

Страница 10: ...10 NE 5020 23 07 18 en 004A...

Страница 11: ...rence y yellow 24 brown 14 green A2 Code The magnetic switch NE 5020 includes a magnetic coded transmitter and a receiver as decoder The semiconductor outputs close when the recei ver recognises the r...

Страница 12: ...open end white 24 V green 0 V brown 24 V switched signal yellow 0 V switched signal or M8 M12 connector pin configuration see drawing Length of cable 4 m according to UL Style 2464 Mounting Screw M4...

Страница 13: ...de s curit Interrupteur magnetique cod NE 5020 Fiche Technique Manuel d utilisation FRAN AIS E DOLD S HNE KG B P 1251 78114 Furtwangen Allemagne T l 49 7723 6540 Fax 49 7723 654356 dold relays dold co...

Страница 14: ...onnement 17 Sch ma bloc 17 Homologations et sigles 17 Autres informations ce sujet 17 Utilisations 17 R alisation et fonctionnement 17 Raccordement 17 Affichages 17 Remarques 17 Caract ristiques techn...

Страница 15: ...ropri es ne sont pas prises ATTENTION Met en garde contre les actions qui peuvent causer des dommages au materiel Software ou hardware suite un mauvais fonctionne ment de l appareil ou de l environnem...

Страница 16: ...16 NE 5020 23 07 18 fr 004A...

Страница 17: ...ot g contre les courants de court circuit et les impulsions de tensions parasites L interrupteur magnetique NE 5020 doit tre raccord au module BG 5925 920 ou LG 5925 920 conform ment l exemple L inter...

Страница 18: ...e 10 55 Hz IEC EN 60 068 2 6 R sistance climatique 25 060 04 IEC EN 60 068 1 Connectique 4 conducteurs avec embout blanc 24 V vert 0 V marron 24 V signal de commutation jaune 0 V signal de commutation...

Страница 19: ...Accessoires DE Auswerteger te f r Magnetschalter NE 5020 EN Control units for magnetic switch NE 5020 FR Modules d interpr tation pour interrupteur magnetique NE 5020 DE Anschlu belegung Steckervarian...

Страница 20: ...onformit tserkl rung EN CE Declaration of Conformity FR D claration de conformit europ enne E DOLD S HNE KG D 78114 Furtwangen e mail dold relays dold com internet http www dold com Bregstra e 18 Tele...

Отзывы: