![Dolby Laboratories DSP100 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/dolby-laboratories/dsp100/dsp100_user-manual_2516707055.webp)
Dolby
®
Digital Cinema Presentation System User’s Manual
43
Chapter 4
System Maintenance
This
chapter
explains
how
to
maintain
the
Dolby
®
Show
Store
and
Dolby
Show
Player.
The
sections
that
follow
show
you
how
to
diagnose
and
repair
hard
drives
and
power
supplies.
4.1
Maintaining the Show Store Internal Hard Drives
If
one
of
the
Show
Store’s
internal
hard
drives
fails,
its
corresponding
front
‐
panel
LED
turns
from
green
to
red,
as
shown
in
the
example
in
Figure 4-1
Identifying a Failed Drive in the Show Store
If
a
drive
fails
while
a
show
is
running,
the
show
continues
to
run
without
interruption.
If
one
drive
fails,
no
information
is
lost.
If
a
second
drive
fails
before
you
replace
the
first
failed
drive,
all
information
is
lost
(and
any
show
in
progress
stops
running).
For
this
reason,
you
should
replace
a
failed
drive
as
soon
as
possible.
4.1.1
Replacing a Drive
To
replace
a
Show
Store
internal
hard
drive:
1.
Note
the
front
‐
panel
number
that
corresponds
to
the
problem
drive
(the
number
next
to
the
red
LED).
2. Remove
the
Show
Store’s
front
panel
by
placing
one
hand
on
its
left
side
and
one
hand
on
its
right
side,
then
pulling
it
toward
you
until
it
disengages
from
the
main
unit,
as
shown
in
4
3
2
1
!
Failed drive LED
(Drive 1)
Failed drive LED
(Drive 1)