DOL 46R Скачать руководство пользователя страница 4

 

 

 

 

 

 

2

018.11

.29

 • 

60

4337

 •

 17

.11

 •

 EN •

 Mad

e in

 Den

m

ark

 

dol-sensors a/s

           Hedelund 4, Glyngøre           7870 Roslev           Denmark           Tlf. +45 72 17 58 88           Fax +45 72 17 59 59           

www.dol-sensors.com

 

SPECIFIC CONDITIONS OF USE 

 
 

FUNCTIONS AND FEATURES 

• 

Use in hazardous areas according to the classification 
(group II, category IIIC, apparatus for dust atmosphere). 
Complies with the requirements of the standards EN/IEC 60079-0 and EN/IEC 60079-31. 

• 

Label information 

 II 1 D Ex ta IIIC T

200

 85 

o

C Da 

II: The sensor is classified for explosion group II, which concerns all remaining risk areas but mines 
1: Category 1. The sensor can be used in zone: 

20: Flammable material present continuously or long periods. 

21: Flammable material present occasionally. 

22: Flammable material present in abnormal conditions for short periods. 

D: For use in hazardous areas, in which explosive dust are present. 

Ex: Conforms to the Harmonized Standards. 

ta: Protection by enclosure, highest level 

IIIC: Conductive dust. 

T

200

 85 

o

C: The max. surface temperature of the sensor, 85

 o

C. 

Da: EPL Da. See Category 1 D above. 

 

• 

Permissible operating temperature of the application (proper usage): 

Ta: -30°C...+50°C

 

 

MAINTENANCE / REPAIR 

The unit must not be modified nor can it be repaired. In case of a fault please contact the manufacturer. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание 46R

Страница 1: ...C T200 85 o C Da The DOL 46R capacitive relay sensor series is designed for general detection of feed grain and solids Certified according to ATEX directive 2014 34 EU and IECEx for operation in potential explosive dust atmospheres Classified as equipment for use in atmospheres with continuous presence of explosive dust with an ignition temperature above 85 oC Robust design with plastic housing wi...

Страница 2: ... Use the black wires 1 and 4 NOTE The internal relay is in position NC when the supply voltage is connected and the sensor is activated wire 1 and 4 are connected Figure 2 No current sensor USER S GUIDE Easy trimmer adjustment on a single turn 240 trimmer with linear or non linear scale Functions which can be made available for adjustment on trimmers ON and or OFF delay MaxRunTimer Sensitivity DOL...

Страница 3: ... non explosive Adhere to the relevant national regulations and provisions The relevant installation regulations must be adhered to In particular take into account the requirements relating to the temperature limitation as regards the expected dust deposits Avoid electrostatic charging on housings and cables In case of cleaning the sensor this must be done with a damp cloth in order to prevent buil...

Страница 4: ... all remaining risk areas but mines 1 Category 1 The sensor can be used in zone 20 Flammable material present continuously or long periods 21 Flammable material present occasionally 22 Flammable material present in abnormal conditions for short periods D For use in hazardous areas in which explosive dust are present Ex Conforms to the Harmonized Standards ta Protection by enclosure highest level I...

Отзывы: