DOL 46R Скачать руководство пользователя страница 2

 

 

 

 

 

 

2

018.11

.29

 • 

60

4337

 •

 17

.11

 •

 EN •

 Mad

e in

 Den

m

ark

 

dol-sensors a/s

           Hedelund 4, Glyngøre           7870 Roslev           Denmark           Tlf. +45 72 17 58 88           Fax +45 72 17 59 59           

www.dol-sensors.com

 

TECHNICAL USER GUIDE 

 

PRODUCT DESCRIPTION: 

DOL 46R is a capacitive relay sensor for 
detection of feed, grain and solids. The 
sensors have relay output including switch 
function. Certified according to ATEX 
directive 2014/34/EU and IECEx for 
operation in potential explosive dust 
atmospheres. Classified as high-level 
equipment for use in atmospheres with 
continuous presence of explosive dust with 
an ignition temperature above 85 °C. 

Fields of application: 

• Level control in silos and containers 
• Controlling the filling and emptying 
process. 

 

MOUNTING GUIDE (FIG. 1): 

DOL 46R is made in a ø30 mm smooth 
design mounted in a gland. 

Figure 1 

 

 

INSTALLATION GUIDE (FIG. 2): 

Supply voltage is connected to the blue and 
brown wire. 
The load is connected in series with the 
relay contact of the sensor. 

STOP

 by activating the sensor: Use the 

black wires 1 and 3. 

START

 by activating the sensor: Use the 

black wires 1 and 4. 

NOTE!

 The internal relay is in position NC 

when the supply voltage is connected and 
the sensor is activated - wire 1 and 4 are 
connected. 

 

Figure 2: No-current sensor 

 

 

USER’S GUIDE: 

 

Easy trimmer adjustment on a 
single turn 240° trimmer with 
linear or non-linear scale.  

 

Functions which can be made 
available for adjustment on 
trimmers: 

ON and/or OFF delay 

MaxRunTimer 

Sensitivity 

DOL 46R has a red LED, indicating 
sensor status and a green LED 
indicating power on.  
Fig. 3 shows examples of LED 
sequences.  

Figure 3 

 
 

 

 

 

 

TECHNICAL DATA: 

Supply voltage: 

Voltage: 

20 - 280 V AC/DC 

Frequency 

47 - 63 Hz 

Relay: 

Max. resistive load,  
250 VAC: 

4 A 

Max. inductive load,  
250 VAC:  

2 A 

Min. relay current,  
12 VDC 

100 mA 

Temperature: 

Temp. 
operation: 

- 30 °C - + 50 °C 

- 22 °F - + 122 °F 

Temp. storage: 

- 40 °C - + 80 °C 

- 40 °F - + 176 °F 

Degree of protection: 

IP: 

69K 

NEMA: 

1, 3, 4, 6, 12, 13 

Cable:

 

Length: 

2 m, 5 m or 10 m 

6.6, 16.5 or 33 feet 

Conductor 
dimensions: 

5 x 0.5 mm

5 x AWG20 

Dimensions: 

 

 

Approvals: 

ATEX zone 20, 21 and 22, dust 
EN/IEC conforms to the Harmonized 
standards 
CE

0539

  

 II 1D Exta IIIC T

200

 85 

o

C Da 

 

 

Relay NC (1-4) 

 

 

 

Relay NO (1-3) after delay 

 

 

 

LED- sequence 

NC (1-4) 

NO (1-3) 

LED 
 
NC (1-4) 

NO (1-3) 

LED 
 
NC (1-4) 

NO (1-3) 

LED 

Sensor 
 
 
 
No time 
 delay 
 
 
 
Delayed 
discon- 
nection 
 
 
 
Delayed 
connec- 
tion 

Содержание 46R

Страница 1: ...C T200 85 o C Da The DOL 46R capacitive relay sensor series is designed for general detection of feed grain and solids Certified according to ATEX directive 2014 34 EU and IECEx for operation in potential explosive dust atmospheres Classified as equipment for use in atmospheres with continuous presence of explosive dust with an ignition temperature above 85 oC Robust design with plastic housing wi...

Страница 2: ... Use the black wires 1 and 4 NOTE The internal relay is in position NC when the supply voltage is connected and the sensor is activated wire 1 and 4 are connected Figure 2 No current sensor USER S GUIDE Easy trimmer adjustment on a single turn 240 trimmer with linear or non linear scale Functions which can be made available for adjustment on trimmers ON and or OFF delay MaxRunTimer Sensitivity DOL...

Страница 3: ... non explosive Adhere to the relevant national regulations and provisions The relevant installation regulations must be adhered to In particular take into account the requirements relating to the temperature limitation as regards the expected dust deposits Avoid electrostatic charging on housings and cables In case of cleaning the sensor this must be done with a damp cloth in order to prevent buil...

Страница 4: ... all remaining risk areas but mines 1 Category 1 The sensor can be used in zone 20 Flammable material present continuously or long periods 21 Flammable material present occasionally 22 Flammable material present in abnormal conditions for short periods D For use in hazardous areas in which explosive dust are present Ex Conforms to the Harmonized Standards ta Protection by enclosure highest level I...

Отзывы: