DOL 130412 Скачать руководство пользователя страница 8

Technical User Guide

8

www.dol-sensors.com

DOL 94-10

6. Mount the rubber plug and cap again.

7 Maintenance

• The scale should be kept free of litter and dirt.

• The scale should be calibrated at least once a year.

The scale is not subject to daily attendance. However, it is important that the settings made in the controller
concerning weighing of poultry are correct. Otherwise, the average weight of the birds will not be calculated
correctly.

• Check on a regular basis that the number of approved weighings is not less than 100 birds each day.

If the number of weighings falls to less than 100, it may be a result of the settings for search limits and refer-
ence weight in the controller not being correct. See also the User's Manual of the controller.

7.1 Batch End - Catching

• Remove the scale before catching.

• Clean the scale thoroughly. It stands heavy cleaning, such as high-pressure cleaning with the cap in place.

• Before disinfection, remove the cap by turning it.

• When using plug connections, remember to mount the dust caps.

• The scale should be stored in a dry room between the batches.

It is important that the scale is removed from the livestock house before catching the birds to ensure that
it is not damaged. If multiple scales are placed in the same house, it is important that these a not mixed
up when cleaning. Put marks on the scales to ensure that each is connected to the same connector after
cleaning.

Содержание 130412

Страница 1: ...DOL 94 10 Bird scale For other language variants of this document we refer to www dol sensors com or your local dealer dol sensors a s Agro Food Park 15 DK 8200 Aarhus N T 45 7217 5888 F 45 7217 5959...

Страница 2: ...ct description DOL 94 10 poultry scale is capable of weighing animals up to 10 kg The weighing cell of the scale converts the weight of the bird to a voltage This voltage is intensified and ad justed...

Страница 3: ...ug four pole female Cable plug four pole male Dust cap 693 female plug Dust cap 693 male plug 3 Mounting Guide 1 Place the scale on the floor and check that it is in a stable position where there is g...

Страница 4: ...10 4 Recommended tools Below follows a list of tools recommended for installation of the DOL 94 10 Item Description Cordless drill Screwdriver bits Utility knife Multimeter Tape measure Side cutter N...

Страница 5: ...onal standard EN 60204 1 and any other EU standards that are applicable in Europe The installation of a power supply isolator is required for each motor and power supply to facili tate voltage free wo...

Страница 6: ...Technical User Guide 6 www dol sensors com DOL 94 10 5 3 Circuit diagram Example of poultry scale connected to production controller The exact connection depend on the other connections Poultry scale...

Страница 7: ...r and dirt 5 Remove the rubber plug Press the button to start calibration Press the button to start calibration 1 Place the cap upside down on the end of the top frame so the electric module is uncove...

Страница 8: ...sult of the settings for search limits and refer ence weight in the controller not being correct See also the User s Manual of the controller 7 1 Batch End Catching Remove the scale before catching Cl...

Страница 9: ...utput signal V 0 kg 0 5 10 kg 10 00 Output impedance 1 Mechanical Cable dimensions mm 6 8 Capacity kg 0 10 Accuracy 0 3 Max overload 150 of capacity Environment Temperature operation C F 10 to 45 14 t...

Страница 10: ...Technical User Guide 10 www dol sensors com DOL 94 10...

Страница 11: ...Technical User Guide DOL 94 10 www dol sensors com 11...

Страница 12: ...Technical User Guide dol sensors a s Agro Food Park 15 DK 8200 Aarhus N T 45 7217 5888 F 45 7217 5959 www dol sensors com 604388 2020 07 29 en US Made in Denmark...

Отзывы: