DOL 130412 Скачать руководство пользователя страница 3

Technical User Guide

DOL 94-10

www.dol-sensors.com

3

2 Product survey

130412 DOL 94-10 platform scale

Is used for weighing of broilers and breeders.

Supplied with 3 m cable.

Capacity: 10 kg

Supply voltage: 11 – 30 V DC

Output signal: 0 kg = 0.5 V / 10 kg = 10.00 V.

130418 DOL 94-10 Platform scale with plug

Is used for weighing of broilers and breeders.

Supplied with 3 m cable with plug.

Capacity: 10 kg

Supply voltage: 11 – 30 V DC

Output signal: 0 kg = 0.5 V / 10 kg = 10.00 V.

2.1 Accessories

130961 M12x1 circular connection plug

Is used if DOL 94-10 cable needs to be extended.

Consists of:

– Cable plug four-pole female

– Cable plug four-pole male

– Dust cap 693 female plug

– Dust cap 693 male plug

3 Mounting Guide

1. Place the scale on the floor and check that it is in a stable position:

– where there is great movement activity, typically between water and feed lines.

– approx. 1/3 down in the house and where the scale can be seen from the entrance of the livestock

house.

– so the cable can easily be led through the litter to the wall, post or ceiling.

– so the birds cannot fly against the cable or peck the cable into pieces.

2. Connect the scale to the production controller.

DOL 94-10 is a precision product and thus requires careful handling.

Do not expose the scale to impacts or loads exceeding 10 kg. Do not step on the scale.

Permanent damage to the load cell is a risk if it is dropped.

Содержание 130412

Страница 1: ...DOL 94 10 Bird scale For other language variants of this document we refer to www dol sensors com or your local dealer dol sensors a s Agro Food Park 15 DK 8200 Aarhus N T 45 7217 5888 F 45 7217 5959...

Страница 2: ...ct description DOL 94 10 poultry scale is capable of weighing animals up to 10 kg The weighing cell of the scale converts the weight of the bird to a voltage This voltage is intensified and ad justed...

Страница 3: ...ug four pole female Cable plug four pole male Dust cap 693 female plug Dust cap 693 male plug 3 Mounting Guide 1 Place the scale on the floor and check that it is in a stable position where there is g...

Страница 4: ...10 4 Recommended tools Below follows a list of tools recommended for installation of the DOL 94 10 Item Description Cordless drill Screwdriver bits Utility knife Multimeter Tape measure Side cutter N...

Страница 5: ...onal standard EN 60204 1 and any other EU standards that are applicable in Europe The installation of a power supply isolator is required for each motor and power supply to facili tate voltage free wo...

Страница 6: ...Technical User Guide 6 www dol sensors com DOL 94 10 5 3 Circuit diagram Example of poultry scale connected to production controller The exact connection depend on the other connections Poultry scale...

Страница 7: ...r and dirt 5 Remove the rubber plug Press the button to start calibration Press the button to start calibration 1 Place the cap upside down on the end of the top frame so the electric module is uncove...

Страница 8: ...sult of the settings for search limits and refer ence weight in the controller not being correct See also the User s Manual of the controller 7 1 Batch End Catching Remove the scale before catching Cl...

Страница 9: ...utput signal V 0 kg 0 5 10 kg 10 00 Output impedance 1 Mechanical Cable dimensions mm 6 8 Capacity kg 0 10 Accuracy 0 3 Max overload 150 of capacity Environment Temperature operation C F 10 to 45 14 t...

Страница 10: ...Technical User Guide 10 www dol sensors com DOL 94 10...

Страница 11: ...Technical User Guide DOL 94 10 www dol sensors com 11...

Страница 12: ...Technical User Guide dol sensors a s Agro Food Park 15 DK 8200 Aarhus N T 45 7217 5888 F 45 7217 5959 www dol sensors com 604388 2020 07 29 en US Made in Denmark...

Отзывы: