Manual transducerized BMT series
DOC.60425-05/21
27
8.3.3 Engaging Torque detection
②
It is possible only when the screw engaging provide significantly higher torque than previous free run.
Speed
Unit
Range
Initial
rpm
Tool range
0
Description
Tool rotation speed
Torque (%)
Unit
Range
Initial
%
0 ~ 50
0
Description
Engaging torque setting by percentage of target torque – detection will be active from
this value
Angle limit
Unit
Range
Initial
0.1 turn
0 ~ 20
0
Description
Max engaging rotation in rev
Time limit
Unit
Range
Initial
sec
0 ~ 10
0
Description
Max engaging timelap
Angle start from engaging
Unit
Range
Initial
YES - NO
NO
Description
If select, the monitoring angle count is reset and start again from engaging torque
detection.point.
② or ④