11.3.2 Fastening errors
Code
Nombre
Description
FASTENING TIMOUT
300
Over time limit on A242(Forward run time limit)
LOOSENING TIMOUT
301
Over time limit on A243(Loosen run time limit)
OVER TIME LOOSEN
304
Motor stall by loosening failure within time limit on A244
OVER_TRQ_BEFORE_RAMP_UP
305
Target torque reached before seating point and ramp up.
MIN ANGLE
330
Target torque reached before the Min angle
TARGET ANGLE SET
331
Target angle setting is out of the range [AC/TM mode]
MAX ANGLE
332
Target torque reached over the Max angle
FASTENING STOP
333
Operation stops before complete cycle of torque up by releasin
g lever trigger
FIND ENGAGING TQ
334
The engaging torque is not detected in time or angle limit
C_TORQUE LIMIT
335
Converted torque is out of torque limit (%)
FASTEN OVER TQ
336
Torque reached to the high limit of torque capacity
TQ_UP DURING F_SPEE
337
Torque up when free speed zone
THREADTAP MAX TORQUE
338
Torque reached when ThreadTap max torque zone
THREADTAP MIN MAX
RANGE OVER
339
Over ThreadTap torque Min, Max range
OVER TEMP MOTOR
500
Motor temperature over 80°C
OVER TEMP BATTEY
501
Battery temperature over 80°C