background image

Page 25

Program-Change Remote-Control

Function

Midi-instruction

Hex-Code ( Midichannel 16 = F)

select row 1

PRG-Change 1

CF 00

select row 2

PRG-Change 2

CF 01

select row 3

PRG-Change 3

CF 02

entire row active

PRG-Change 4

CF 03

entire row off

PRG-Change 5

CF 04

All steps of a row
active individually

PRG-Change 6

CF 05

All steps of a row
off individually

PRG-Change 7

CF 06

Betriebsarten:
Forward (FOr)

PRG-Change 9

CF 08

Backward (bAC)

PRG-Change 10

CF 09

Pendulum 1 (PE1)

PRG-Change 11

CF 0A

Random (rnd)

PRG-Change 12

CF 0B

Step 1 on

PRG-Change 17

CF 10

Step 2 on

PRG-Change 18

CF 11

...

.....

.....

Step 16 off

PRG-Change 32

CF 1F

Step 1 off

PRG-Change 33

CF 20

Step 2 off

PRG-Change 34

CF 21

...

.......

......

Step 16 aus

PRG-Change 48

CF 2F

First Step = 1

PRG-Change 49

CF 30

First Step = 2

PRG-Change 50

CF 31

...

......

.....

First Step = 16

PRG-Change 64

CF 3F

Last Step = 1

PRG-Change 65

CF 40

Last Step = 2

PRG-Change 66

CF 41

...
Last Step =16

PRG-Change 80

CF 4F

Event Contr. 0

PRG-Change 81

CF 50

Event Contr. 1

PRG-Change 82

CF 51

...
Event Contr. 31

PRG-Change 112

CF 6F

Event NA1

PRG-Change 113

CF 70

Event NA2

PRG-Change 114

CF 71

...

......

.......

Event NA5

PRG-Change 117

CF 74

Event Nr1

PRG-Change 118

CF 75

Event Nr2

PRG-Change 119

CF 76

...
Event Nr5

PRG-Change 122

CF 79

Event Pit

PRG-Change 123

CF 7A

Event PIP

PRG-Change 124

CF 7B

Event PI-

PRG-Change 125

CF 7C

Содержание MAQ16/3

Страница 1: ...DOEPFER MIDI Analog Sequencer MAQ16 3 User s Guide...

Страница 2: ...0 Menu 6 SINGLE STEP 10 Menu 7 PRESET 10 Menu 8 START STOP 10 Detailed Description of the Menus 11 EVENT 12 CHANNEL 17 FIRST LAST STEP 17 PRESCALE 17 MODE 18 SINGLE STEP 19 PRESET 20 START STOP 22 APP...

Страница 3: ...use the instrument in a humid or wet environment nor near inflammables No liquids or conducting materials must get into the instrument If this should happen the instrument must be disconnected from p...

Страница 4: ...r the safety of your data Same is valid for the MAQ data too For this purpose the MAQ has the dump feature that enables to store your preset data via MIDI SysEx messages e g to a computer or MIDI reco...

Страница 5: ...x It was thoroughly tested by our firm as well as several beta testers and found to be free of bugs Nevertheless it has been our experience that the new version of a software package will eventually r...

Страница 6: ...C unstabilized as well as a minimum current of 500mA The polarity of the connector must be the following ring GND tip 9V DC If the polarity of the power supply is incorrect the MAQ16 3 will not functi...

Страница 7: ...cteristics used by most of the vintage synthesizers 1 semitone 1 12V 0 083V In all other cases e g controller the voltage range is about 0 25V knob full ccw 5 25V knob full cw For each CV output there...

Страница 8: ...er minute which can be altered via the data entry dial The 8 LEDs above the MENU buttons will be off i e no menu is selected If this is not the case either the MAQ16 3 or the power supply is defective...

Страница 9: ...or to discussing them in detail Menu 1 EVENT In this menu a certain type of MIDI instruction Event is assigned to each row The most important event types are Note ON OFF Velocity Controller Pitch bend...

Страница 10: ...he desired sequence is not to be determined experimentally but a prepared sequence is to be entered The function can also be used for interesting effects during live performances Scanning of a sequenc...

Страница 11: ...re comfortable glimming display The data potentiometer of V1 0 2 0 has been replaced by an endless rotary encoder alpha dial Realtime Operation All parameters in menus 1 6 can be altered during operat...

Страница 12: ...ve nr5 1 5 octaves 1 d Y n Dynamics Velocity 2 C0 C1 C2 Controller 9 PIt Pitch Bend 3 PIP Pitch Bend positive only 3 PI Pitch Bend negative only 3 At After Touch monophonic Prg Program Change 4 Cn1 MI...

Страница 13: ...ocity row then the note instructions are sent with a velocity value of 100 If a note row is combined with a poly pressure row see remark 7 then the note row no longer sends Note ON OFF instructions bu...

Страница 14: ...nction to work properly an appropriatenumber of receivers Expanders must be available on several MIDI channels MIDI Multimode Expanders which can receive on several different channels simultaneously l...

Страница 15: ...hen the step in question will be omitted i e this serves as SKIP function The timing of each row is also influenced by an adjustable prescale factor Menu 4 PRESCALE TIME If the step duration function...

Страница 16: ...to now Therefore you now have of course to define these values if you want to use them in a preset Relating to a dump of a single preset the 3 new bytes are simply put at the end of the string So to...

Страница 17: ...ces and can also be used for improvisations or experimental pieces PRESCALE In this menu the period between two events in MIDI clock units can be adjusted for each row For note events the note duratio...

Страница 18: ...Clock gesteuert random PE2 Pendelmodus 2 Clock gesteuert OnS Einfach Durchlauf 1 Clock gest One Shot Onr Einfach Durchlauf 2 Clock gest OnE Einzelnote Clock gesteuert nFr vorw rts Noten gesteuert nbC...

Страница 19: ...0 the data value of a single setp is displayed only in the Single Step Mode for a Single Row see below If you press the menu button once again you enter the Single Step Mode for a single Row In this...

Страница 20: ...f a sequence but should also be used for experimentation during live performances PRESET This global menu is used to manage the 30 available presets and to manually trigger the DUMP function Up to 30...

Страница 21: ...48 potentiometer values you only have to turn the knob in question The software recognizes if a knob was turned and takes in this case the value from the front panel knob and no longer from the preset...

Страница 22: ...lisation the MAQ must be turned off and on again to enter the regular mode Presets initialized imply the parameters from preset 0 i e event type nA1 for all rows MIDI channel 1 2 3 first step 1 last s...

Страница 23: ...EtS or EtC In case of EtS external trigger start mode only an incoming MIDI Start event resets the 3 rows to first step An incoming MIDI Continue the sequence continues from the last position In case...

Страница 24: ...s XX and YY as an expander would Instead the MAQ s main parameters which can be viewed as events which make musical sense are controlled via PRG Note Adjusting the MIDI channels XX and YY In order to...

Страница 25: ...F 10 Step 2 on PRG Change 18 CF 11 Step 16 off PRG Change 32 CF 1F Step 1 off PRG Change 33 CF 20 Step 2 off PRG Change 34 CF 21 Step 16 aus PRG Change 48 CF 2F First Step 1 PRG Change 49 CF 30 First...

Страница 26: ...ecessitated by programming considerations Noten Event Fernsteuerfunktionen MIDI Channel YY here f e channel 16 F Row 1 Step 1 Note 36 9F 8F 24 XX Row 1 Step 2 Note 37 9F 8F 25 XX Row 1 Step 16 Note 51...

Страница 27: ...In case of a MIDI error the MAQ shows an error code in the display You may continue by pressing the Start Stop button But as the reason is normally a grave error you should store the actual sequence i...

Страница 28: ...x notation If the MAQ receives a string like this it will answer with a Sys Ex Dump string consisting of exactly 4106 Byte length over all Attention Please make sure that this string has a length exac...

Страница 29: ...ng integrated circuits and eventually for the trimming potentiometers of the CV outputs special tool for removing integrated circuits with PLCC case pliers or wrench for potentiometer alpha dial and C...

Страница 30: ...ween the first hole and the power supply hole should be about 110 mm so that the analog board does not overlap with the basic board Mount the analog board using the 6 jack sockets at the rear panel Co...

Страница 31: ...er Doepfer or an authorized service company Otherwise you will loose your warranty We will send you a list of all authorized service companies upon request Not correctly adjusted CV scale is no reason...

Страница 32: ...Page 32 Doepfer Musikelektronik www doepfer com 2001 by Doepfer Musikelektronik...

Отзывы: