External Synchronisation
In order to synchronize the MAQ16/3 with an external MIDI-clock via MIDI-IN, one must turn
the data-entry dial all the way over the maximum (254) or minimum value (50). The display
will then show „EtS“ or „EtC“ .
In case of „EtS“ (external trigger start mode) only an incoming MIDI Start event resets the 3
rows to first step. An incoming MIDI Continue the sequence continues from the last position.
In case of „EtC“ (external trigger continue mode) incoming MIDI Start or Continue resets the
3 rows as well.
When „EtS“ or „EtC“ is selected no longer the internal Clock generator is used but only