background image

CONNECTORS

Our decoders use easy-to.-use screwlles cage clamp conn-
nectors. Please use a standard flat blade screw driver to
open the clamps (a standard phase tester will be just fine) -
never use a phillipps-, pozidrive aor torx tool since this may
damage the levers.

To open, gentlöy press, insert wire and release. You’re do-
ne!. Cage clamp connectors accept both, stranded and so-
lid wires. We recommend to use ferrules with stranded wi-
res whenever poosible.

The  decoder 7044B-H consits of connectors for these inputs and outputs:

CN6

POWER SUPPLY  230V AC 50 Hz

1

black:

L

230V AC

2

blue:

N

    0V AC

CN5

DALI Data bus

1

grey

DALI OUT

2

grey

DALI OUT

CN4

DMX Data input

1 (grey)

GND, Screen

connects to XLR Pin 1

2 (blue)

Control signal -

connects to XLR Pin 2

3 (orange) Control 

connects to XLR Pin 3

CN5: DALI OUT

CN4: DMX IN

CN6: 230V AC

Содержание soundlight 7044B-H

Страница 1: ...CKED CAREFULLY AND ARE BELIEVED TO BE ACCURATE HOWEVER SOUNDLIGHT DOES NOT ASSUME ANY RESPONSIBI LITY FOR ERRORS OR OMISSIONS THE USER HAS TO CHECK THE SUITABILITY OF THE EQUIP MENT FOR THE INTENDED U...

Страница 2: ...mpatible The 7044B H is compatible to DALI bus systems simple supply The power supply is from standard mains voltage 230V AC signal loss In the case of a loss of the drive signal a pre definable actio...

Страница 3: ...u re do ne Cage clamp connectors accept both stranded and so lid wires We recommend to use ferrules with stranded wi res whenever poosible The decoder 7044B H consits of connectors for these inputs an...

Страница 4: ...to re program connected DALI responders to a fade time of at least 0 7 sec fade time parameter set to 1 or 2 to allow a smooth response You may do so using your preferred DALI programmer or our USB D...

Страница 5: ...o meet your individual needs More information regarding DALI programming and the USB DALI interface can be found in the USB DALI manual It is not necessary to use the USB DALI programmer Any DALI prog...

Страница 6: ...programmed into the interface both status LEDs are blinking alternatively several times As soon as the programming sequence is completed upower the decoder re set the desired DMX start address and re...

Страница 7: ...5 address mode etc 864 set to enable 64 address mode NOTE Pls note that converting more than 4 adresses simultaneously may cause significant delays due to the limited DALI bus speed TECHNICAL DATA Dim...

Страница 8: ...ace in a closed conductive e g metal housing which must be connected to GND Please make sure that shielded data cable is used and the shield is connected properly to the GND pin Shield must never make...

Страница 9: ...ign manuals are available from www ma nuals soundlight de Additional RDM information for RDM enabled devices only is available from www rdm soundlight de If you have any comments which may be worth co...